제품

Microscopes

Metallographic / biological / DIC

HX metallurgical microscopes (mono/binocular/trinocular, upright/inverted, BF/DF) and WF differential-interference microscopes with HXGXS analysis software for microstructure, grain size and inclusion rating.

Metallographic / biological / DIC

Microscopes · 100 모델

AMM-8ST Metallurgical Microscope

AMM-8ST Metallurgical Microscope

Metallurgical Microscope

  • 大型研发倒置卧式金相显微镜大型研发数码倒置卧式金相显微镜 / 大型研发视频图像倒置卧式金相显微镜 / 大型研发图像处理倒置卧式金相显微镜 / 大型研发数据处理倒置卧式金相显微镜
  • 1、目镜筒卧式三目镜筒、双目、45度倾斜 瞳距55-75mm
AMM-17 Metallurgical Microscope

AMM-17 Metallurgical Microscope

Metallurgical Microscope

  • 正置明暗视场透反射金相显微镜数码正置明暗视场透反射金相显微 / 视频图像正置明暗视场透反射金相显微镜 / 图像处理正置明暗视场透反射金相显微镜 / 数据处理正置明暗视场透反射金相显微镜
  • 1、目镜标配:大视野 WF10X(视场数Φ22mm)
AMM-200 Metallurgical Microscope

AMM-200 Metallurgical Microscope

Metallurgical Microscope

  • 三目正置金相显微镜数码三目正置金相显微镜 / 视频图像三目正置金相显微镜 / 图像处理三目正置金相显微镜 / 数据处理三目正置金相显微镜
  • 1、目镜WF10X(直径18mm)、WF16X(直径11mm)
PM-11 Polarizing Microscope (透、反射)

PM-11 Polarizing Microscope (透、反射)

Polarizing Microscope · 透、反射

  • 光学放大倍数40~600X、50~600X
  • 目镜大视野WF10X(Φ18mm)、分划目镜10X (Φ18mm),0.10mm/格;PM-11A无应力平场消色差物镜(盖玻片0.17mm)PL:4X/0.;10X/0.;40X/0.65(弹簧)、60X/0.85(弹簧)
PM-12 Polarizing Microscope (透射)

PM-12 Polarizing Microscope (透射)

Polarizing Microscope · 透射

  • 光学放大倍数40~1000X、40~600X
  • 目镜大视野WF10X(Φ18mm)、分划目镜10X (Φ18mm),0.10mm/格;PM-12A无应力平场消色差物镜(盖玻片0.17mm)PL/POL:4X/0.10\17.94工作距离、10X/0.25\8.
01

측정 원리

Microscopes

The metallurgical microscope uses an infinity-corrected optical path with reflected Köhler illumination. Light passes the collector, field stop and aperture stop, is deflected by a semi-transparent mirror through the objective onto the specimen, and returns through the same objective to the eyepiece or camera.

  • Bright field for routine microstructure, inclusions and decarburised layers.
  • Dark field collects scattered light to reveal grain boundaries, cracks and non-metallic inclusions.
  • Polarised light identifies anisotropic phases, spheroidised structures and coating stress.
  • DIC converts tiny height differences into contrast, ideal for polished, unetched samples.

Objectives of 5× to 100× are combined with 10× eyepieces. Higher numerical aperture gives better resolution but shallower depth of field.

02

Process animation

Microscopes

  1. Sampling and preparation: sectioning, mounting, grinding, polishing, etching.
  2. Illumination and focus: select BF/DF/POL/DIC and focus.
  3. Image capture: trinocular port, 1× camera adapter, white balance.
  4. Scale calibration: calibrate µm per pixel with a stage micrometer.
  5. Measurement: grain size, case depth, coating thickness, inclusion rating.
0102030405
03

Calculation & formulas

Microscopes

1. System magnification: M = objective × eyepiece × adapter, e.g. 40× / 10× / 1× = 400×.

2. Resolution: d = 0.61λ/NA (λ≈550 nm). A 40× objective with NA 0.65 resolves 0.52 µm; an NA 0.95 dry objective reaches 0.35 µm.

3. Depth of field scales with λ/NA² — higher NA, shallower depth; use low NA for fracture surfaces.

4. Grain size (GB/T 6394): at 100×, grains N per 645 mm² field follow N = 2G−1; counting 128 grains gives G = log2128 + 1 = 8. Intercept method: mean intercept L̄ = line length ÷ intercepts, G = −6.6437 lg L̄ (mm, 100×).

5. Effective case depth: distance to 550 HV1, fitted from a micro-hardness traverse and averaged over three positions.

04

규격

Microscopes

StandardTitleScope
GB/T 13298-2015Metallic materials — examination of microstructureMicrostructure rating
GB/T 6394-2017Determination of average grain sizeGrain size
ASTM E3-11Guide for metallographic specimen preparationPreparation
ASTM E112Determining average grain sizeGrain size
ISO 643Steels — micrographic determination of grain sizeGrain size

Export projects often require dual GB and ASTM reports; the software ships both rating charts.

05

선택 가이드

Microscopes

1. Surface or cross-section: stereo microscopes (HX-ZG7, XSZ) for fracture surfaces, solder joints and coatings; upright or inverted metallurgical microscopes (HX-4, HX-G series) for microstructure, case depth and inclusions.

2. Upright or inverted: upright for small specimens that are flipped often; inverted (HX-G3A/G4C/G5A) for large, heavy parts such as gears, shafts and tube sections that go straight onto the stage without re-mounting.

3. Optics set the ceiling: plan achromats cover routine rating; semi-apochromats or apochromats with a research stand (HX-G5A) are needed for 1000× precipitates and brightfield/darkfield/polarised switching.

4. Three levels of digitalisation: a 5 MP camera for images; camera plus analysis software (grain size, case depth, inclusions, porosity) for automatic rating and reports; motorised stage with scanning and stitching for unattended batches.

5. Do not forget accessories: polariser, darkfield, DIC, and a microhardness interface.

6. Room: an anti-vibration bench at 20±3 °C for research stands; keep preparation and microscopy rooms separate to avoid abrasive dust.

SeriesTypeTypical taskRecommended setup
HX-4A / HX-4BUpright metallurgicalRoutine structure, case depth5×/10×/40× + 5 MP camera
HX-G2A / G2BInvertedBatch samples, no re-mountingBrightfield + simple polariser
HX-G3ATrinocular invertedCase depth, rating, reportsCamera + analysis software
HX-G4C / G5AResearch invertedDarkfield/polarised/DICSemi-apochromat + motorised stage
HX-ZG7 / XSZ-146StereoFracture, solder, low-mag locatingZoom + ring light

Common misconceptions: higher magnification is not better (numerical aperture limits resolution, 100× dry is the practical ceiling); ignoring stage travel so large samples do not fit; buying the stand without software and still rating by eye, which kills repeatability.

06

시험 방법

Microscopes

Preparation. Section perpendicular to the feature of interest. Keep hot-mounting below 150 °C for aluminium and quenched parts, or use cold mounting. Grind 320→600→800→1200, removing previous scratches at each step; polish with 3 µm then 1 µm diamond. Etchants: 4% nital for carbon steel (3–8 s), aqua regia or electrolytic for stainless, Keller for aluminium.

Examination. Locate a representative field at 5×/10×, then switch to higher power. Rate grain size to GB/T 6394 by comparison or intercept. Measure case depth at 500× with an ocular scale or calibrated software, averaging five readings.

Calibration. Verify µm/pixel daily with a stage micrometer, check against a certified specimen quarterly, record three fields per sample and archive images with scale bars.

Pitfalls. Over-etching widens boundaries and fakes decarburisation; residual scratches can be mistaken for cracks; rounded mounting edges inflate case depth. Keep an unetched specimen for coating and crack review.

07

Industry applications

Microscopes

  • Steel and heat treatment: decarburised depth, carburised/nitrided case depth, grain size (GB/T 6394), non-metallic inclusions (GB/T 10561), banding and Widmanstätten rating.
  • Non-ferrous metals: aluminium grain and recrystallisation, alpha/beta ratio in brass, twinning and corrosion morphology in magnesium.
  • Welding and brazing: penetration, HAZ width, porosity and cracks, intermetallic thickness at dissimilar joints.
  • Additive manufacturing: porosity, lack-of-fusion defects, melt-pool morphology in SLM parts, porosity repeatability within 0.2%.
  • Bearings and gears: martensite rating, retained austenite, carbide network and banding, grinding burn and white layer.
  • Electronics: IMC thickness, plating cross-sections, PCB micro-sections, gold wire ball bonds (stereo plus metallurgical).
  • Powders and ceramics: particle morphology and size, sintered porosity, coating cross-section thickness.
  • Failure analysis: fracture surface macro and micro morphology, corrosion products, crack path and origin, with stereo microscopy for low-magnification locating.
적용 사례

적용 사례

전체 보기→

Price and lead time for this model

엔지니어가 1영업일 내에 선정안, 검사 기준, 납기를 제안합니다.

⇄0비교사양 비교