제품

Vision Measuring Systems

Manual, CNC, gantry

YR-series video measuring machines and vertical profile projectors from 100×100 to 1200×1500 mm; CNC models run programmed batch inspection for stamped parts, mouldings, PCB and precision hardware.

Manual, CNC, gantry

Vision Measuring Systems · 25 모델

01

측정 원리

Vision Measuring Systems

Vision measuring systems replace contact metrology with imaging: backlight turns part edges into a high-contrast silhouette, while surface and coaxial light reveal bores, blind holes and steps. After capture, software extracts sub-pixel edges, fits lines, circles and arcs by least squares, establishes a part coordinate system (3-2-1 or best-fit) and computes distances, angles, concentricity and position tolerance.

The stage is driven by servo motors and precision screws with linear encoder feedback (0.1–1 µm). CNC models automate the move–capture–measure sequence for batch inspection. Accuracy is typically stated as U = 2.0 + L/200 µm at 20 ± 2 °C.

  • Telecentric lenses remove perspective error for deep bores and steps.
  • Bi-telecentric optics with parallel backlight give the sharpest edges on stamped parts.
  • Laser or touch probes add Z height and deep-hole capability.
02

Process animation

Vision Measuring Systems

  1. Load and clamp: part on the glass stage, vacuum or fixture.
  2. Alignment: three points define datum plane and axis.
  3. Imaging: switch contour/surface light, autofocus and exposure.
  4. Edge extraction: sub-pixel gradient search along the normal.
  5. Fit and compute: least-squares lines, circles, arcs; GD&T evaluation.
  6. Report: Excel/PDF with out-of-tolerance items flagged.
0102030405
03

Calculation & formulas

Vision Measuring Systems

1. Indication error: commonly E = (2.5 + L/150) µm (L in mm); at L = 200 mm, E ≈ 3.83 µm, verified with a glass ruler along the diagonals.

2. Pixel size: field width ÷ active pixels; an 8 mm field on 1280 px gives 6.25 µm/px, improved to 1/10 px by sub-pixel algorithms.

3. Circle fit: σ(diameter) ≈ σpoint/√n — use ≥16 points per least-squares circle.

4. True position: deviation Δ = 2√(Δx² + Δy²) versus tolerance zone φt; Δx=0.02, Δy=0.015 mm gives Δ = 0.05 mm.

5. Thermal correction: 100 mm of steel changes 1.2 µm per °C (α≈11.5×10⁻⁶/°C) — apply on the shop floor.

04

규격

Vision Measuring Systems

StandardTitleUse
GB/T 24762-2009GPS — acceptance and reverification tests for imaging instrumentsAcceptance, annual check
JJF 1318-2011Calibration specification for vision measuring instrumentsCalibration
ISO 10360-7Acceptance tests for CMMs with imaging probing systemsExport projects
VDI/VDE 2617Accuracy of coordinate measuring machinesAccuracy rating
GB/T 1958-2017GPS — verification of geometrical toleranceGD&T
05

선택 가이드

Vision Measuring Systems

1. Calculate travel first: maximum part envelope plus fixture plus approach margin, then add 20%. Sizing on the part alone is the classic mistake. YRVMS covers 150×100 to 1200×1500; larger parts need YRVMS5030 or gantry models.

2. Three accuracy numbers, not one: indication error (E), repeatability (R) and scale resolution. E = 2.5+L/200 µm is standard, 1.8+L/300 µm for precision work; a 0.001 mm display means nothing on its own.

3. Manual, motorised or CNC: manual (YRVMS1510F) for sampling, motorised (YRVMS2010E and up) for repetitive batches, CNC (YRVMS3020CNC and up) for programmed multi-feature and unattended runs.

4. Optics and lighting decide capability: 0.7–4.5× zoom with bi-telecentric optics for planar dimensions; laser or touch probe for height, blind holes and deep slots; coaxial light for polished metal, backlight for transparent parts.

5. Software, three questions: can it build a coordinate system from drawing datums rather than by eye, does it output FAI/PPAP sheets, and does it support SPC and Excel export.

6. In-line inspection is a different machine: use YR-MV for cycle-time-driven 100% inspection instead of a measuring machine.

SeriesDriveTravel (mm)Typical use
YRVMS1510FManual150×100Small-part sampling, teaching
YRVMS2010E / 2515FMotorised / manual200×100 / 250×150Connectors, precision hardware
YRVMS3020CNC / 4030CNCCNC300×200 / 400×3003C FAI, batch programming
YRVMS5030 / 5030CNCCNC500×300Mid-size structural parts
YRVMS120150Gantry CNC1200×1500Sheet and large contours
YR-MV1080 / 7070Dedicated visionCustomIn-line 100% inspection
YR-QVS seriesFlash measurementSmall fieldOne-click multi-dimension

Acceptance advice: verify E with a glass scale after installation, check R by measuring the same part ten times, then compare against a part with known CMM results; the deviation should stay within E.

06

시험 방법

Vision Measuring Systems

Environment. 20 ± 2 °C, 40–60% RH, vibration-free; warm up 30 minutes; soak parts at least 2 hours (4 for large parts).

Calibration. Measure a glass scale or ceramic gauge block at near and far positions in X/Y/Z; perform ISO 10360-7 probing in seven directions with a length standard.

Measurement. Establish the coordinate system (plane–line–point or 3-2-1); take at least five points per feature (six for a circle, eight for a large circle); avoid chamfered edges; repeat each feature three times.

Verification. Check daily with a known artefact (50 mm block, certified circle); recalibrate when deviation exceeds one third of MPE.

Uncertainty. Dominated by temperature (11.5 × 10⁻⁶/°C × L), encoder error, edge algorithm and clamping repeatability; state U at k = 2.

07

Industry applications

Vision Measuring Systems

  • 3C and precision parts: phone frames, laptop housings, camera modules with 140+ first-article dimensions; repeatability ≤2 µm and FAI first-pass rate ≥95%.
  • Connectors and terminals: coplanarity, pitch, pin offset; high-magnification small field with bi-telecentric optics, coplanarity repeatability ≤3 µm.
  • Medical devices: syringe needles, stent struts, instrument edges; non-contact with archived images for GMP traceability.
  • Stamping and hardware: high-speed in-line inspection at ≤1 s per part with rotary or conveyor feeding.
  • PCB and FPC: hole diameter, line width and spacing, gold-finger dimensions; coaxial and programmable lighting for 0.05 mm lines.
  • Fine gears and watch parts: profile and cumulative pitch error of gears below module 0.2.
  • Battery cells: coating width, tab dimensions, can flatness in dust and corrosion controlled areas.
  • Moulds and electrodes: copper and graphite electrode contour and depth, complementary to CMM.
적용 사례

적용 사례