BID-400 · 2026-11-17 · +86 21 5748 2007
BID-400 Biological Microscope
Biological Microscope
- 光学放大倍数100X~400X
- 机械筒长∞
- 物镜共轭距离∞
- 目镜大视野WF10X(Φ22mm)、对中目镜
By submitting you agree to our privacy policy.
제품 개요
BID-400倒置偏光调制相衬显微镜是一种多功能生物显微镜,适配我公司近期研发的偏光调制相衬观察系统,适用于相位物体、双折射物体、染色试样、柱状物体以及具有表面和次表面特征的物体进行高分辨率显微观察,可对细胞组织、透明液态组织、培养皿中的培养组织进行动态显微观察及科研分析。主要应用于科研院所、高等院校、医疗卫生、检验检疫、农牧乳业等部门。
调制相衬观察是通过将光的相位梯度转换为光强度变化,这样可以对通常看不见的相位物体形成一个高衬度、高分辨率的像,成像以三维立体状态显示出来,主要应用于相位物体、双折射物体、染色试样、柱状物体以及具有表面和次表面特征的物体进行高分辨率显微观察。本仪器匹配转盘式调制相衬聚光镜或拉板式调制相衬聚光镜,并与近期研发调制相衬物镜(10X,20X,40X)配套使用,无论是高倍还是低倍观察都能呈现出清晰明亮且富有立体感的视场效果。
一、性能特点:
1、铰链式双目观察镜筒,镜筒45度倾斜;
2、高品质透明玻璃载物台板,很好降低载物台受热变形影像,物镜转换过程清晰可见;
3、高强度同轴挠性钢丝传动,极限位置自动保护功能,配备三种不同培养皿托板,适用于不同培养皿观察;
4、一体化照明系统,同时配备旋转式聚光系统,科迪高培养皿或圆筒状烧瓶进行无沾染培养细胞观察;
5、大视野目镜,视场范围直径22mm;
6、高品质相衬平场物镜与相衬聚光镜,拉板式和转盘式两种类型;
7、后置式摄影摄像接口设计,摄影摄像不干扰目镜观察;100%通光适合低照度的显微摄影摄像。
二、技术参数:
光学放大倍数:100X~400X;
机械筒长:∞;
物镜共轭距离:∞;
目镜:大视野WF10X(Φ22mm)、对中目镜;
目镜:铰链双目,观察角度为45度,瞳距为53~75毫米;
目镜接口:Ф30mm;
齐焦距离:10mm;
无限远长距平场消色差物镜PLL(盖玻片厚度1.2mm):10X/0.25\工作距离19.4mm,20X/0.4\8.0mm,40X/0.6\3.5mm;
无限远长距平场消色差相衬物镜PHP(盖玻片厚度1.2mm):10X/0.25\工作距离4.3mm;
目镜筒:三目镜(倾斜45度),瞳距53~75mm;
调制相衬物镜(盖玻片厚度1.2mm):10X/0.25\工作距离4.3mm、20X/0.40\工作距离8.0mm、40X/0.60\工作距离3.5mm;(需与相衬聚光镜装置中的狭缝相匹配)。
明视场物镜(盖玻片厚度1.2mm):10X/0.25\工作距离4.3mm;
转换器:五孔转换器;
长工作距离聚光镜:长工作距离聚光镜,工作距离55mm,转盘式调制相衬装置,调制相衬观察适应;
载物台:双层机械移动式,227*208mm,移动范围77mm*134.5mm,移动尺可拆卸;
调焦机构:粗微动同轴调节,微动手轮格植:0.002毫米;
培养皿托板一:86mm(宽)X129.5mm(长),可适配圆形培养皿Ф87.5mm;
培养皿托板二:34mm(宽)X77.5mm(长),可适配圆形培养皿Ф68.5mm;
培养皿托板三:57mm(宽)X82mm(长);
光源:6V/30W卤素灯,亮度可调;
三、选配配件:
1、明视场物镜:20X/0.4\工作距离8mm、40X/0.6\工作距离3.5mm;(适合于明视场观察)。
2、相衬物镜:10X/0.25\工作距离4.3mm、20X/0.4\工作距离8mm、40X/0.6\工作距离3.5mm;(适合于相位相衬观察,需与相衬聚光镜中相衬环板相匹配);
3、转换器:六孔转换器;
4、长工作距离聚光镜:工作距离55mm,拉板式调制相衬装置,调制相衬观察适应;
5、长工作距离聚光镜:工作距离55mm,转盘式或拉板式相衬装置,相位相衬观察适应;
6、长工作距离聚光镜:工作距离55mm,带可变孔径光阑,明视场普通观察适应;
7、光源:大功率LED照明;
BID-400 Biological Microscope supplied by CHWES. 16 key specifications available on request.
사양
| 光学放大倍数 | 100X~400X |
|---|---|
| 机械筒长 | ∞ |
| 物镜共轭距离 | ∞ |
| 目镜 | 大视野WF10X(Φ22mm)、对中目镜 |
| 目镜接口 | Ф30mm |
| 目镜筒 | 三目镜(倾斜45度),瞳距53~75mm |
| 调制相衬物镜(盖玻片厚度1.2mm) | 10X/0.25\工作距离4.3mm、20X/0.40\工作距离8.0mm、40X/0.60\工作距离3.5mm;(需与相衬聚光镜装置中的狭缝相匹配) |
| 明视场物镜(盖玻片厚度1.2mm) | 10X/0.25\工作距离4.3mm |
| 转换器 | 五孔转换器 |
| 长工作距离聚光镜 | 长工作距离聚光镜,工作距离55mm,转盘式调制相衬装置,调制相衬观察适应 |
| 载物台 | 双层机械移动式,227*208mm,移动范围77mm*134.5mm,移动尺可拆卸 |
| 调焦机构 | 粗微动同轴调节,微动手轮格植:0.002毫米 |
| 培养皿托板一 | 86mm(宽)X129.5mm(长),可适配圆形培养皿Ф87.5mm |
| 培养皿托板二 | 34mm(宽)X77.5mm(长),可适配圆形培养皿Ф68.5mm |
| 培养皿托板三 | 57mm(宽)X82mm(长) |
| 光源 | 6V/30W卤素灯,亮度可调 |
* Generated by rule engine over the product database; for pre-selection only.
측정 원리
The metallurgical microscope uses an infinity-corrected optical path with reflected Köhler illumination. Light passes the collector, field stop and aperture stop, is deflected by a semi-transparent mirror through the objective onto the specimen, and returns through the same objective to the eyepiece or camera.
- Bright field for routine microstructure, inclusions and decarburised layers.
- Dark field collects scattered light to reveal grain boundaries, cracks and non-metallic inclusions.
- Polarised light identifies anisotropic phases, spheroidised structures and coating stress.
- DIC converts tiny height differences into contrast, ideal for polished, unetched samples.
Objectives of 5× to 100× are combined with 10× eyepieces. Higher numerical aperture gives better resolution but shallower depth of field.
Process animation
- Sampling and preparation: sectioning, mounting, grinding, polishing, etching.
- Illumination and focus: select BF/DF/POL/DIC and focus.
- Image capture: trinocular port, 1× camera adapter, white balance.
- Scale calibration: calibrate µm per pixel with a stage micrometer.
- Measurement: grain size, case depth, coating thickness, inclusion rating.
Calculation & formulas
1. System magnification: M = objective × eyepiece × adapter, e.g. 40× / 10× / 1× = 400×.
2. Resolution: d = 0.61λ/NA (λ≈550 nm). A 40× objective with NA 0.65 resolves 0.52 µm; an NA 0.95 dry objective reaches 0.35 µm.
3. Depth of field scales with λ/NA² — higher NA, shallower depth; use low NA for fracture surfaces.
4. Grain size (GB/T 6394): at 100×, grains N per 645 mm² field follow N = 2G−1; counting 128 grains gives G = log2128 + 1 = 8. Intercept method: mean intercept L̄ = line length ÷ intercepts, G = −6.6437 lg L̄ (mm, 100×).
5. Effective case depth: distance to 550 HV1, fitted from a micro-hardness traverse and averaged over three positions.
규격
| Standard | Title | Scope |
|---|---|---|
| GB/T 13298-2015 | Metallic materials — examination of microstructure | Microstructure rating |
| GB/T 6394-2017 | Determination of average grain size | Grain size |
| ASTM E3-11 | Guide for metallographic specimen preparation | Preparation |
| ASTM E112 | Determining average grain size | Grain size |
| ISO 643 | Steels — micrographic determination of grain size | Grain size |
Export projects often require dual GB and ASTM reports; the software ships both rating charts.
선택 가이드
1. Surface or cross-section: stereo microscopes (HX-ZG7, XSZ) for fracture surfaces, solder joints and coatings; upright or inverted metallurgical microscopes (HX-4, HX-G series) for microstructure, case depth and inclusions.
2. Upright or inverted: upright for small specimens that are flipped often; inverted (HX-G3A/G4C/G5A) for large, heavy parts such as gears, shafts and tube sections that go straight onto the stage without re-mounting.
3. Optics set the ceiling: plan achromats cover routine rating; semi-apochromats or apochromats with a research stand (HX-G5A) are needed for 1000× precipitates and brightfield/darkfield/polarised switching.
4. Three levels of digitalisation: a 5 MP camera for images; camera plus analysis software (grain size, case depth, inclusions, porosity) for automatic rating and reports; motorised stage with scanning and stitching for unattended batches.
5. Do not forget accessories: polariser, darkfield, DIC, and a microhardness interface.
6. Room: an anti-vibration bench at 20±3 °C for research stands; keep preparation and microscopy rooms separate to avoid abrasive dust.
| Series | Type | Typical task | Recommended setup |
|---|---|---|---|
| HX-4A / HX-4B | Upright metallurgical | Routine structure, case depth | 5×/10×/40× + 5 MP camera |
| HX-G2A / G2B | Inverted | Batch samples, no re-mounting | Brightfield + simple polariser |
| HX-G3A | Trinocular inverted | Case depth, rating, reports | Camera + analysis software |
| HX-G4C / G5A | Research inverted | Darkfield/polarised/DIC | Semi-apochromat + motorised stage |
| HX-ZG7 / XSZ-146 | Stereo | Fracture, solder, low-mag locating | Zoom + ring light |
Common misconceptions: higher magnification is not better (numerical aperture limits resolution, 100× dry is the practical ceiling); ignoring stage travel so large samples do not fit; buying the stand without software and still rating by eye, which kills repeatability.
시험 방법
Preparation. Section perpendicular to the feature of interest. Keep hot-mounting below 150 °C for aluminium and quenched parts, or use cold mounting. Grind 320→600→800→1200, removing previous scratches at each step; polish with 3 µm then 1 µm diamond. Etchants: 4% nital for carbon steel (3–8 s), aqua regia or electrolytic for stainless, Keller for aluminium.
Examination. Locate a representative field at 5×/10×, then switch to higher power. Rate grain size to GB/T 6394 by comparison or intercept. Measure case depth at 500× with an ocular scale or calibrated software, averaging five readings.
Calibration. Verify µm/pixel daily with a stage micrometer, check against a certified specimen quarterly, record three fields per sample and archive images with scale bars.
Pitfalls. Over-etching widens boundaries and fakes decarburisation; residual scratches can be mistaken for cracks; rounded mounting edges inflate case depth. Keep an unetched specimen for coating and crack review.
Industry applications
- Steel and heat treatment: decarburised depth, carburised/nitrided case depth, grain size (GB/T 6394), non-metallic inclusions (GB/T 10561), banding and Widmanstätten rating.
- Non-ferrous metals: aluminium grain and recrystallisation, alpha/beta ratio in brass, twinning and corrosion morphology in magnesium.
- Welding and brazing: penetration, HAZ width, porosity and cracks, intermetallic thickness at dissimilar joints.
- Additive manufacturing: porosity, lack-of-fusion defects, melt-pool morphology in SLM parts, porosity repeatability within 0.2%.
- Bearings and gears: martensite rating, retained austenite, carbide network and banding, grinding burn and white layer.
- Electronics: IMC thickness, plating cross-sections, PCB micro-sections, gold wire ball bonds (stereo plus metallurgical).
- Powders and ceramics: particle morphology and size, sintered porosity, coating cross-section thickness.
- Failure analysis: fracture surface macro and micro morphology, corrosion products, crack path and origin, with stereo microscopy for low-magnification locating.