Cold rolls require Ra 0.2–0.4 µm and 0.05 mm crown. The plant used a portable roughness tester plus分段 micrometer readings: two setups, 35 minutes, and no way to detect grinding chatter.
Solution: a CX-3/160 profile instrument with 160 mm travel, one setup scanning along the generatrix, outputting Ra/Rz and the crown curve together; the software overlays the theoretical crown and flags deviation above 0.01 mm.
Result: 12 minutes per roll, chatter detected reliably, and the grinding rework rate fell from 6% to 2.1%.