Mechanical seal faces need Ra ≤0.1 µm and waviness ≤0.2 µm. Ra always passed, yet high-temperature bench tests occasionally leaked, and teardown showed slight circumferential waviness.
Solution: XZ-230 profilometer with 230 mm travel, four radial and four circumferential traces per face, Gaussian filtering to separate roughness from waviness and evaluate W separately, plus flatness.
Result: Ra of 0.08 µm passed while waviness of 0.4 µm failed, caused by excessive lapping-plate speed producing periodic cutting; lower speed and a spark-out pass brought waviness to 0.12 µm and bench leakage from 1.8% to 0.2%.