The seatbelt retractor bracket is a 2.5 mm high-strength steel stamping with a hole-pitch tolerance of ±0.06 mm. Calipers plus a projector took six minutes per piece, and the two inspectors often disagreed, causing disputes on borderline parts.
Solution: a YR3020Z manual zoom vision machine with a 6.5:1 continuous zoom lens, transmitted plus ring illumination, measuring hole pitch, flange height and bend angle in one clamping; X/Y indication error is ±(3+L/200) µm, and the software judges against the tolerance band automatically.
Result: 50 seconds per piece with repeatability within 3 µm; the inspector-to-inspector difference fell from 0.03 mm to below 0.005 mm.
Benefit: sampling frequency tightened from every two hours to every 30 minutes, so early die wear is caught half a shift sooner.