기술 자료848 views

2.5D vs 3D Vision Measurement: Z-Axis Capability, Principle Differences and Selection Boundaries

2.5D adds Z via focus or laser for step heights; true 3D needs tactile probes, structured light or white-light interferometry — an order of magnitude apart in accuracy and cost.

华旋光电技术部
2.5D vs 3D Vision Measurement: Z-Axis Capability, Principle Differences and Selection Boundaries

Where 2.5D gets its Z

A conventional vision machine is intrinsically two-dimensional: X/Y come from linear scales, and Z only drives focusing. The so-called 2.5D Z measurement follows two paths: focus-based, searching the contrast evaluation function for the sharpest position with repeatability of about 1 to 3 μm, suitable for transparent parts and step heights; or an optional laser triangulation or chromatic confocal head reaching ±(2-5) μm over a 10 to 30 mm range. 2.5D fits planar parts with a few height features, such as PCBs, stampings and phone structural parts.

Three routes to true 3D

RouteAccuracyThroughputBest for
Vision plus tactile probe (multisensor)±(3+L/200) μmMediumHole depth, side walls, occluded features
Structured light / line laser scanning±(10-30) μmHighFreeform surfaces, reverse engineering
White-light interferometry / confocal0.01-0.1 μmLowSurface texture, microstructures

Selection criteria

Look at the spatial distribution of features: coplanar features with a few steps are fine for 2.5D; side holes, deep slots and 3D surfaces demand true 3D. Then accuracy: within 5 μm in Z, a multisensor machine is the only economical choice; sub-micron needs push you to white-light interferometry, which trades tiny fields of view and no large-part capability. Material matters too: lasers dislike mirror surfaces, transparent parts suit confocal heads, soft materials need non-contact.

Multisensor coordination

The key to a vision-plus-tactile machine is unifying the two coordinate systems: calibrate the offset between the optical center and the probe ball center with a reference sphere, typically tens of microns, and after calibration both sensors should agree within ±5 μm on the same feature. Programs can then mix calls — optics for the outer profile, probe for hole depth — finishing full dimensional inspection in one setup, which is exactly the core value of multisensor machines.

⇄0비교사양 비교