MC003-PLARM Portable platinum measuring arm

Full 3D dimensional and GD&T inspection

ModellMC003-PLARM
  • Control便携式关节测量臂,6 轴/7 轴
  • Accuracy接触式测头 + 可选激光扫描头
  • Measuring range按型号规格,详见选型表
  • Software专业测量与评价软件(尺寸/形位公差)

By submitting you agree to our privacy policy.

01

Überblick

The MC003-PLARM solution covers portable arms to high-accuracy bridge CMMs, with touch probes or laser scanning.

The MC003-PLARM solution covers portable arms to high-accuracy bridge CMMs, with touch probes or laser scanning.

02

Technische Daten

Control便携式关节测量臂,6 轴/7 轴
Accuracy接触式测头 + 可选激光扫描头
Measuring range按型号规格,详见选型表
Software专业测量与评价软件(尺寸/形位公差)
Profile parameters适用于箱体、叶片、模具、结构件全尺寸检测

* Generated by rule engine over the product database; for pre-selection only.

03

Messprinzip

A bridge CMM carries the probe along X/Y/Z on linear scales resolving 0.01–0.1 µm class. Touch-trigger probes lock coordinates on contact; scanning probes stream surface points; non-contact laser heads capture millions of points per second for free-form or soft parts.

A 21-term geometric error model (positioning, straightness, squareness, angularity) is compensated in software, with thermal sensors correcting at α = 11.5×10⁻⁶/°C for steel.

Portable arms (MC003) serialise six encoded joints, solving the tip position by the D-H model — on-site measurement of large parts; with a laser head they become reverse-engineering scanners.

04

Process animation

  1. Fixturing: free clamping, checked for probe collisions.
  2. Probe calibration: qualify the stylus on a reference sphere.
  3. Alignment: 3-2-1 or CAD best-fit datum.
  4. Execution: the program drives points and scans automatically.
  5. Evaluation: GD&T rules per ISO 1101 / ASME Y14.5.
  6. Reporting: colour deviation maps with traceable point records.
0102030405
05

Calculation & formulas

1. Two-point distance: d = √(Δx²+Δy²+Δz²) with u(d) ≈ √2·uaxis.

2. Thermal: ΔL = L·α·ΔT; a 300 mm steel part 2 °C off nominal shifts 6.9 µm — correct or measure at 20 °C.

3. True position: Δ = 2√(Δx²+Δy²) versus φt; Δx=0.03, Δy=0.04 mm gives Δ=0.10 mm, failing φ0.08.

4. Uncertainty budget: uc = √(ucmm²+uprobe²+utemp²+ufixturing²); with 1.8, 0.6, 1.0 and 0.8 µm terms uc ≈ 2.3 µm (U ≈ 4.6 µm, k=2).

5. Roundness: least-squares roundness = max(ri)−min(ri); arbitration by minimum zone.

06

Normen

StandardTitleScope
ISO 10360-2CMM acceptance and re-verification, Part 2MPE_E0 testing
GB/T 16857.2GPS — CMM acceptance in ChinaNational acceptance
ISO 1101GPS — geometrical tolerancingGD&T evaluation
GB/T 1958GPS — detection of geometrical deviationsForm-error methods
ISO/TS 15530-3Uncertainty assessment for CMMsTask-specific U budgets

Job sheets must record temperature, probe configuration, point strategy and fixturing for reproducibility.

07

Auswahl

1. Locate by accuracy and travel: set travel from the largest part plus 150–200 mm for fixturing, then pick accuracy from the tolerance. MPE_E 2.2+L/350 covers most automotive and general work, 1.8+L/300 precision moulds, below 1.2+L/300 aerospace and gauge work.

2. Structure follows the part: bridge machines (Atlas, Daisy) for small and mid-size batches; gantry (ML) for heavy parts; arms (MC003-SCANARM) for large parts on site; shop-floor machines (DuraMax, Spectrum) next to the line.

3. Probes define capability: touch-trigger for dimensions and GD&T, scanning for surfaces and point clouds, laser for fast reverse engineering. Budget probe and software together with the frame.

4. Software is the long-term cost: DMIS program exchange, native GD&T evaluation rather than custom scripting, PPAP/FAI output, offline programming.

5. Environment is a precondition: 20±2 °C, gradient ≤1 °C/h, vibration ≤VC-C. Buying accuracy without a controlled room wastes money.

6. Accept to ISO 10360: MPE_P with a standard sphere plus MPE_E, and ask for the 21-parameter error compensation report.

SeriesStructureMPE_ETypical use
DaisyBridge, economy2.5+L/300General hardware, teaching
Atlas / Atlas-BBridge2.2+L/350Automotive parts, housings
MGH high accuracyBridge, rigid1.2+L/300Precision moulds, gauges
ML seriesGantry3.0+L/300Large structures, castings
UG / SpectrumShop-floor3.5+L/300Near-line inspection
MC003-SCANARMArm with scanning0.03 mm (arm dependent)Large parts on site, reverse engineering
MC003-GAGEPLUSDedicated gaugePart specificFast batch go/no-go

What drives the price: accuracy class, travel, probe and scanning package, software modules, temperature room and air supply. The same travel can differ two to three times, so never compare frame price alone.

08

Prüfverfahren

Environment: 20±1 °C, gradient ≤0.5 °C/h, 40–60% RH; soak parts ≥4 h (overnight for large ones).

Fixturing: 3- or 6-point support without clamping distortion; low-stress support paste for thin walls.

Datums: 3-2-1 from drawing features; otherwise CAD best-fit, logging RMS residuals.

Point strategy: 4–6 points on ≤10 mm holes, ≥6 points over the full plane, scan spacing ≤0.5 mm on free forms.

Checks: reference sphere or gauge block each shift; quarterly ISO 10360 interim checks archived.

Pitfalls: thermal soak shortcuts, over-long styli, excessive scan speed, mis-built datums.

09

Industry applications

  • Automotive and EV: position and profile tolerances on e-drive housings, transmission casings and battery trays with 200+ features per part; MPE_E ≤2.2+L/350 µm.
  • Moulds and die casting: cavity surface comparison, electrode-to-mould clearance, first-article and repair verification with scanning probes and point-cloud software.
  • Aerospace: GD&T and free-form surfaces on structural parts, impellers and casings per ASME Y14.5 and ISO 1101 datum systems.
  • Precision machinery: straightness, squareness and flatness of beds and columns, complementary to autocollimators.
  • Medical: free-form and mating dimensions of implants and instruments with traceable reports.
  • Electronics: micro-features on precision parts and packaging moulds, requiring high-accuracy machines in temperature-controlled rooms.
  • Large weldments: excavator booms and wind flanges measured on site with arms or gantry machines.
  • Third-party labs: dimensional arbitration and first-article inspection with valid calibration and uncertainty budgets.
10

Price and lead time for this model

By submitting you agree to our privacy policy.

⇄0VergleichTechnischer Vergleich