Rotary tables & metrology2024

Dual-axis indexing calibration of a 360-tooth table

HXM2010-1 dual-axis autocollimator with a 24-face polygon measured a 360-tooth table at ±0.08″ with 0.11″ closure.

Firma
National metrology laboratory
Adresse
Beijing
Dual-axis indexing calibration of a 360-tooth table
±0.08″Index error
2.5 hVerification time

A 360-tooth table serves as a secondary angle standard and must be verified to JJG 283; single-axis procedures were slow and drifted with temperature.

Solution: HXM2010-1 mounted once for a full 24-face sweep, both channels logging polygon and table error simultaneously for separation of errors.

Result: index error ±0.08″ against a ±0.2″ requirement with 0.11″ closure; verification time cut from 6 to 2.5 hours.