A 360-tooth table serves as a secondary angle standard and must be verified to JJG 283; single-axis procedures were slow and drifted with temperature.
Solution: HXM2010-1 mounted once for a full 24-face sweep, both channels logging polygon and table error simultaneously for separation of errors.
Result: index error ±0.08″ against a ±0.2″ requirement with 0.11″ closure; verification time cut from 6 to 2.5 hours.