High-speed elevator rails require straightness within 0.5 mm per 5 m and twist within 0.4 mm. The old method tensioned a wire beside the rail and read it with a microscope; wire sag introduced up to 0.3 mm error over 50 m and one rail took an hour.
Solution: HXM4050M-1 (1″, 50 m) with a bridge and magnetic base, one station every 5 m for 11 stations; the autocollimator stays at one end while the mirror travels, straightness evaluated by the end-point method and twist read on the second axis.
Result: 12 minutes per rail, repeatability within 0.05 mm, 0.06 mm deviation from CMM sampling; out-of-tolerance sections are identified on site for straightening, raising first-pass yield from 88% to 96%.