The institute’s 0.2 arcsec autocollimator could not meet the uncertainty budget for grade-0 angle gauges (±1 arcsec limit), restricting its angle traceability business.
Solution: YR-0.1S (0.01 arcsec resolution, ±0.1 arcsec MPE) combined with a precision indexing table forms the calibration rig; the four-position method per JJG 70 removes polygon eccentricity, with evaluated uncertainty U=0.15 arcsec (k=2).
Result: the facility passed the national standard assessment and now calibrates 400+ grade-0 gauges and polygons yearly for more than 200 corporate labs across the province.