HOT
MMAS-29 · 2026-11-17 · +86 21 5748 2007
MMAS-29 Metallurgical Microscope (微分干涉)
Metallurgical Microscope · 微分干涉
- 目镜大视野无色差SWF10X(视场数Φ22mm)
- PLL50X/0.70,工作距离3068mm
- PLL80X/0.80,工作距离1.25mm
- 目镜筒三目镜30度倾斜(瞳距调节53~75),100%通光摄影
By submitting you agree to our privacy policy.
Überblick
MMAS-29无限远微分干涉相衬偏光金相显微镜测量分析系统适用于对不透明物体的表面形态进行反射式微分干涉相衬观察,也可对透明物体进行透视显微观察。采用优良的无限远光学系统与模块化功能设计理念,可以方便升级系统,实现偏光观察、微分干涉相衬观察等功能,紧凑稳定的高刚性主体,充分体现了显微操作的防振要求。符合人机工程学要求的理想设计,使操作更方便舒适,空间更广阔。适用于金相组织及表面形态的显微观察,是金属学、矿物学、精密工程学研究的理想仪器。 MMAS-29系统配备了研润自主研发的MMAS测量分析系统以及MOS高端光学系统。
技术特点:
1、柯拉照明系统;
2、无限远光学系统;
3、微分干涉观察系统;
技术参数:
目镜:大视野无色差SWF10X(视场数Φ22mm);
长距无限远平场消色差物镜:
LMPlan5X/0.12DIC,工作距离:15mm;
LMPlan10X/0.30DIC,工作距离:10.5mm;
LMPlan20X/0.40DIC,工作距离:4.5mm;
PLL50X/0.70,工作距离:3068mm;
PLL80X/0.80,工作距离:1.25mm;
目镜筒:三目镜30度倾斜(瞳距调节53~75),100%通光摄影;
落射照明系统:12V50W卤素灯,亮度可调;
透射照明:LED;
调焦机构:粗微动同轴调焦,粗动松紧可调,带锁紧和限位装置,微动格值:0.8μm;
转换器:五孔;
载物台:机械式载物台外形尺寸:280mmX270mm,移动范围:204*204mm;
偏光装置:起偏振器,可360度旋转,可推拉切换,检偏振器,可推拉切换;
DIC观察系统:适用于LMPlan5X/LMPlan10X/LMPlan20X DIC物镜;
标准配置:
1、主机;
2、物镜:5只;
3、目镜:1套;
4、适配镜:1X;
5、接口:1只;
6、电脑:1套;
7、MMAS分析系统:1套;
8、随机文件:1套;
选购配件:
1、目镜:分划10X(Φ22mm);
2、物镜:40/0.6/3.98、60/0.7/2.08、100/0.85/0.4(干式);
3、适配镜:0.4X,0.5X,0.5X带分划尺,格值0.1mm/格;
4、VIDEO摄像仪;
5、数码相机;
专业金相测量分析软件功能:
MMAS金相显微测量分析系统的核心功能是根据金相图像进行级别评定。目前以具备400多个按国家及行业标准制作的专业功能模块。
MMAS金相显微测量分析系统具备数十种图像处理功能、同时具备报告处理、几何测量、定倍打印、图像拼接等多种辅助功能。
MMAS金相显微测量分析系统还可以定制图像共聚焦、三维光图等专业功能。
MMAS金相显微测量分析系统是为从事金相检验的单位或个人专门开发的一套计算机软件系统,它的基本原理是:用视频采集卡或数码相机等硬件设备,采集到金相显微镜中的金相图片,再对该图片进行处理和分析,得到相关检验结果。
1.自动评级:
本软件以检验标准为依据,开发出了近百余个类别两百余种软件功能模块,用户可根据需要,选择检验项目,在本软件的帮助下,完成检验工作。
2.新建报告:
可按用户需求制作报告文档的录入界面、软件可自动生成电子报告文档,并提供报告的保存和打印功能。
3.打开报告:
打开并浏览已经保存的报告文件。
4.几何测量:
本软件提供了“直线”、“矩形”、“圆”、“多边形”、“角度”等多种测量工具及测量方法,可完成长度、面积、角度等测量工作。
5.查看图库:
用户可选择查看本软件收录的所有金相图谱,本软件金相图谱由用户提供原始资料,由我方录入。
6.定倍打印:
可一次装入多副图片,并可对其进行图像处理,设置说明文字和打印版面,进而生成一份适合各种行业特殊要求的报告文件。
7.图像拼接:
将采集到的不同视场图像拼接成一幅完整的图像。
7.图像共聚焦:
该功能模块的作用是:将拍摄对象相同、但焦距不同的几张照片,重合成一张清晰的照片。界面及重合效果.
8.三维光图:
本模块通过对图像组织亮度的分析,构建二维图像的三维模型,该软件模块可检查被观测试样是否平整。
MMAS-29 Metallurgical Microscope (微分干涉) supplied by CHWES. 11 key specifications available on request.
Technische Daten
| 目镜 | 大视野无色差SWF10X(视场数Φ22mm) |
|---|---|
| PLL50X/0.70,工作距离 | 3068mm |
| PLL80X/0.80,工作距离 | 1.25mm |
| 目镜筒 | 三目镜30度倾斜(瞳距调节53~75),100%通光摄影 |
| 落射照明系统 | 12V50W卤素灯,亮度可调 |
| 透射照明 | LED |
| 调焦机构 | 粗微动同轴调焦,粗动松紧可调,带锁紧和限位装置,微动格值:0.8μm |
| 转换器 | 五孔 |
| 载物台 | 机械式载物台外形尺寸:280mmX270mm,移动范围:204*204mm |
| 偏光装置 | 起偏振器,可360度旋转,可推拉切换,检偏振器,可推拉切换 |
| DIC观察系统 | 适用于LMPlan5X/LMPlan10X/LMPlan20X DIC物镜 |
* Generated by rule engine over the product database; for pre-selection only.
Messprinzip
The metallurgical microscope uses an infinity-corrected optical path with reflected Köhler illumination. Light passes the collector, field stop and aperture stop, is deflected by a semi-transparent mirror through the objective onto the specimen, and returns through the same objective to the eyepiece or camera.
- Bright field for routine microstructure, inclusions and decarburised layers.
- Dark field collects scattered light to reveal grain boundaries, cracks and non-metallic inclusions.
- Polarised light identifies anisotropic phases, spheroidised structures and coating stress.
- DIC converts tiny height differences into contrast, ideal for polished, unetched samples.
Objectives of 5× to 100× are combined with 10× eyepieces. Higher numerical aperture gives better resolution but shallower depth of field.
Process animation
- Sampling and preparation: sectioning, mounting, grinding, polishing, etching.
- Illumination and focus: select BF/DF/POL/DIC and focus.
- Image capture: trinocular port, 1× camera adapter, white balance.
- Scale calibration: calibrate µm per pixel with a stage micrometer.
- Measurement: grain size, case depth, coating thickness, inclusion rating.
Calculation & formulas
1. System magnification: M = objective × eyepiece × adapter, e.g. 40× / 10× / 1× = 400×.
2. Resolution: d = 0.61λ/NA (λ≈550 nm). A 40× objective with NA 0.65 resolves 0.52 µm; an NA 0.95 dry objective reaches 0.35 µm.
3. Depth of field scales with λ/NA² — higher NA, shallower depth; use low NA for fracture surfaces.
4. Grain size (GB/T 6394): at 100×, grains N per 645 mm² field follow N = 2G−1; counting 128 grains gives G = log2128 + 1 = 8. Intercept method: mean intercept L̄ = line length ÷ intercepts, G = −6.6437 lg L̄ (mm, 100×).
5. Effective case depth: distance to 550 HV1, fitted from a micro-hardness traverse and averaged over three positions.
Normen
| Standard | Title | Scope |
|---|---|---|
| GB/T 13298-2015 | Metallic materials — examination of microstructure | Microstructure rating |
| GB/T 6394-2017 | Determination of average grain size | Grain size |
| ASTM E3-11 | Guide for metallographic specimen preparation | Preparation |
| ASTM E112 | Determining average grain size | Grain size |
| ISO 643 | Steels — micrographic determination of grain size | Grain size |
Export projects often require dual GB and ASTM reports; the software ships both rating charts.
Auswahl
1. Surface or cross-section: stereo microscopes (HX-ZG7, XSZ) for fracture surfaces, solder joints and coatings; upright or inverted metallurgical microscopes (HX-4, HX-G series) for microstructure, case depth and inclusions.
2. Upright or inverted: upright for small specimens that are flipped often; inverted (HX-G3A/G4C/G5A) for large, heavy parts such as gears, shafts and tube sections that go straight onto the stage without re-mounting.
3. Optics set the ceiling: plan achromats cover routine rating; semi-apochromats or apochromats with a research stand (HX-G5A) are needed for 1000× precipitates and brightfield/darkfield/polarised switching.
4. Three levels of digitalisation: a 5 MP camera for images; camera plus analysis software (grain size, case depth, inclusions, porosity) for automatic rating and reports; motorised stage with scanning and stitching for unattended batches.
5. Do not forget accessories: polariser, darkfield, DIC, and a microhardness interface.
6. Room: an anti-vibration bench at 20±3 °C for research stands; keep preparation and microscopy rooms separate to avoid abrasive dust.
| Series | Type | Typical task | Recommended setup |
|---|---|---|---|
| HX-4A / HX-4B | Upright metallurgical | Routine structure, case depth | 5×/10×/40× + 5 MP camera |
| HX-G2A / G2B | Inverted | Batch samples, no re-mounting | Brightfield + simple polariser |
| HX-G3A | Trinocular inverted | Case depth, rating, reports | Camera + analysis software |
| HX-G4C / G5A | Research inverted | Darkfield/polarised/DIC | Semi-apochromat + motorised stage |
| HX-ZG7 / XSZ-146 | Stereo | Fracture, solder, low-mag locating | Zoom + ring light |
Common misconceptions: higher magnification is not better (numerical aperture limits resolution, 100× dry is the practical ceiling); ignoring stage travel so large samples do not fit; buying the stand without software and still rating by eye, which kills repeatability.
Prüfverfahren
Preparation. Section perpendicular to the feature of interest. Keep hot-mounting below 150 °C for aluminium and quenched parts, or use cold mounting. Grind 320→600→800→1200, removing previous scratches at each step; polish with 3 µm then 1 µm diamond. Etchants: 4% nital for carbon steel (3–8 s), aqua regia or electrolytic for stainless, Keller for aluminium.
Examination. Locate a representative field at 5×/10×, then switch to higher power. Rate grain size to GB/T 6394 by comparison or intercept. Measure case depth at 500× with an ocular scale or calibrated software, averaging five readings.
Calibration. Verify µm/pixel daily with a stage micrometer, check against a certified specimen quarterly, record three fields per sample and archive images with scale bars.
Pitfalls. Over-etching widens boundaries and fakes decarburisation; residual scratches can be mistaken for cracks; rounded mounting edges inflate case depth. Keep an unetched specimen for coating and crack review.
Industry applications
- Steel and heat treatment: decarburised depth, carburised/nitrided case depth, grain size (GB/T 6394), non-metallic inclusions (GB/T 10561), banding and Widmanstätten rating.
- Non-ferrous metals: aluminium grain and recrystallisation, alpha/beta ratio in brass, twinning and corrosion morphology in magnesium.
- Welding and brazing: penetration, HAZ width, porosity and cracks, intermetallic thickness at dissimilar joints.
- Additive manufacturing: porosity, lack-of-fusion defects, melt-pool morphology in SLM parts, porosity repeatability within 0.2%.
- Bearings and gears: martensite rating, retained austenite, carbide network and banding, grinding burn and white layer.
- Electronics: IMC thickness, plating cross-sections, PCB micro-sections, gold wire ball bonds (stereo plus metallurgical).
- Powders and ceramics: particle morphology and size, sintered porosity, coating cross-section thickness.
- Failure analysis: fracture surface macro and micro morphology, corrosion products, crack path and origin, with stereo microscopy for low-magnification locating.