MMAS-26 Metallurgical Microscope (明暗场)

Metallurgical Microscope · 明暗场

ModellMMAS-26
  • 目镜大视野WF10X(视场数Φ22mm)
  • PLL5X/0.12BD,工作距离8.05mm
  • PLL10X/0.25BD,工作距离7.86mm
  • PLL20X/0.40BD,工作距离7.23mm

By submitting you agree to our privacy policy.

01

Überblick

MMAS-26无限远明暗场金相显微镜分析系统采用优良的无限远光学系统与模块化的功能设计理念,可以方便升级系统,实现偏光观察、暗场观察等功能。紧凑稳定的高刚性主体,充分体现了显微镜操作的防振要求。符合人机工程学要求的理想设计,使操作更方便舒适,空间更广阔。适用于金相组织及表面形态的显微观察,是金属学、矿物学、精密工程学研究的理想仪器。 MMAS-26系统配备了研润自主研发的MMAS测量分析系统以及MOS高端光学系统。
技术特点:
1、柯拉照明系统;
2、无限远光学系统;
3、明暗场官产系统;
4、后置式摄影装置;
技术参数:
目镜:大视野WF10X(视场数Φ22mm);
无限远平场消色差物镜(明暗场):
PLL5X/0.12BD,工作距离:8.05mm;
PLL10X/0.25BD,工作距离:7.86mm;
PLL20X/0.40BD,工作距离:7.23mm;
PLL50X/0.70BD,工作距离:1.75mm;
目镜筒:三目镜45度倾斜(瞳距调节53~75),后置式摄影接口;
照明系统:12V50W卤素灯,亮度可调;内置视场光栏、孔径光栏、(黄、蓝、绿、磨砂玻璃)滤色片转换装置,推拉式起偏器;
调焦机构:粗微动同轴调焦,带锁紧装置,微动格值:2μm;
转换器:五孔(内向式滚珠内定位) ;
载物台:机械式载物台外形尺寸:242mmX200mm,移动范围:横向30mm,纵向:30mm;
圆形可旋转载物台板:最大外径Ф130mm,最小通光口径小于Ф20mm;
标准配置:
1、主机;
2、物镜:4只;
3、目镜:1套;
4、适配镜:1X;
5、接口:1只;
6、电脑:1套;
7、MMAS分析系统:1套;
8、随机文件:1套;
选购配件:
1、目镜:分划10X(Φ22mm);
2、物镜:40X、60X、80X、100X明/暗场物镜;
3、适配镜:0.5X;
4、VIDEO摄像仪;
5、数码相机;
专业金相测量分析软件功能:
MMAS金相显微测量分析系统的核心功能是根据金相图像进行级别评定。目前以具备400多个按国家及行业标准制作的专业功能模块。
MMAS金相显微测量分析系统具备数十种图像处理功能、同时具备报告处理、几何测量、定倍打印、图像拼接等多种辅助功能。
MMAS金相显微测量分析系统还可以定制图像共聚焦、三维光图等专业功能。
MMAS金相显微测量分析系统是为从事金相检验的单位或个人专门开发的一套计算机软件系统,它的基本原理是:用视频采集卡或数码相机等硬件设备,采集到金相显微镜中的金相图片,再对该图片进行处理和分析,得到相关检验结果。
1.自动评级:
本软件以检验标准为依据,开发出了近百余个类别两百余种软件功能模块,用户可根据需要,选择检验项目,在本软件的帮助下,完成检验工作。
2.新建报告:
可按用户需求制作报告文档的录入界面、软件可自动生成电子报告文档,并提供报告的保存和打印功能。
3.打开报告:
打开并浏览已经保存的报告文件。
4.几何测量:
本软件提供了“直线”、“矩形”、“圆”、“多边形”、“角度”等多种测量工具及测量方法,可完成长度、面积、角度等测量工作。
5.查看图库:
用户可选择查看本软件收录的所有金相图谱,本软件金相图谱由用户提供原始资料,由我方录入。
6.定倍打印:
可一次装入多副图片,并可对其进行图像处理,设置说明文字和打印版面,进而生成一份适合各种行业特殊要求的报告文件。
7.图像拼接:
将采集到的不同视场图像拼接成一幅完整的图像。
7.图像共聚焦:
该功能模块的作用是:将拍摄对象相同、但焦距不同的几张照片,重合成一张清晰的照片。界面及重合效果.
8.三维光图:
本模块通过对图像组织亮度的分析,构建二维图像的三维模型,该软件模块可检查被观测试样是否平整。

MMAS-26 Metallurgical Microscope (明暗场) supplied by CHWES. 11 key specifications available on request.

02

Technische Daten

目镜大视野WF10X(视场数Φ22mm)
PLL5X/0.12BD,工作距离8.05mm
PLL10X/0.25BD,工作距离7.86mm
PLL20X/0.40BD,工作距离7.23mm
PLL50X/0.70BD,工作距离1.75mm
目镜筒三目镜45度倾斜(瞳距调节53~75),后置式摄影接口
照明系统12V50W卤素灯,亮度可调;内置视场光栏、孔径光栏、(黄、蓝、绿、磨砂玻璃)滤色片转换装置,推拉式起偏器
调焦机构粗微动同轴调焦,带锁紧装置,微动格值:2μm
转换器五孔(内向式滚珠内定位)
载物台机械式载物台外形尺寸:242mmX200mm,移动范围:横向30mm,纵向:30mm
圆形可旋转载物台板最大外径Ф130mm,最小通光口径小于Ф20mm

* Generated by rule engine over the product database; for pre-selection only.

03

Messprinzip

The metallurgical microscope uses an infinity-corrected optical path with reflected Köhler illumination. Light passes the collector, field stop and aperture stop, is deflected by a semi-transparent mirror through the objective onto the specimen, and returns through the same objective to the eyepiece or camera.

  • Bright field for routine microstructure, inclusions and decarburised layers.
  • Dark field collects scattered light to reveal grain boundaries, cracks and non-metallic inclusions.
  • Polarised light identifies anisotropic phases, spheroidised structures and coating stress.
  • DIC converts tiny height differences into contrast, ideal for polished, unetched samples.

Objectives of 5× to 100× are combined with 10× eyepieces. Higher numerical aperture gives better resolution but shallower depth of field.

04

Process animation

  1. Sampling and preparation: sectioning, mounting, grinding, polishing, etching.
  2. Illumination and focus: select BF/DF/POL/DIC and focus.
  3. Image capture: trinocular port, 1× camera adapter, white balance.
  4. Scale calibration: calibrate µm per pixel with a stage micrometer.
  5. Measurement: grain size, case depth, coating thickness, inclusion rating.
0102030405
05

Calculation & formulas

1. System magnification: M = objective × eyepiece × adapter, e.g. 40× / 10× / 1× = 400×.

2. Resolution: d = 0.61λ/NA (λ≈550 nm). A 40× objective with NA 0.65 resolves 0.52 µm; an NA 0.95 dry objective reaches 0.35 µm.

3. Depth of field scales with λ/NA² — higher NA, shallower depth; use low NA for fracture surfaces.

4. Grain size (GB/T 6394): at 100×, grains N per 645 mm² field follow N = 2G−1; counting 128 grains gives G = log2128 + 1 = 8. Intercept method: mean intercept L̄ = line length ÷ intercepts, G = −6.6437 lg L̄ (mm, 100×).

5. Effective case depth: distance to 550 HV1, fitted from a micro-hardness traverse and averaged over three positions.

06

Normen

StandardTitleScope
GB/T 13298-2015Metallic materials — examination of microstructureMicrostructure rating
GB/T 6394-2017Determination of average grain sizeGrain size
ASTM E3-11Guide for metallographic specimen preparationPreparation
ASTM E112Determining average grain sizeGrain size
ISO 643Steels — micrographic determination of grain sizeGrain size

Export projects often require dual GB and ASTM reports; the software ships both rating charts.

07

Auswahl

1. Surface or cross-section: stereo microscopes (HX-ZG7, XSZ) for fracture surfaces, solder joints and coatings; upright or inverted metallurgical microscopes (HX-4, HX-G series) for microstructure, case depth and inclusions.

2. Upright or inverted: upright for small specimens that are flipped often; inverted (HX-G3A/G4C/G5A) for large, heavy parts such as gears, shafts and tube sections that go straight onto the stage without re-mounting.

3. Optics set the ceiling: plan achromats cover routine rating; semi-apochromats or apochromats with a research stand (HX-G5A) are needed for 1000× precipitates and brightfield/darkfield/polarised switching.

4. Three levels of digitalisation: a 5 MP camera for images; camera plus analysis software (grain size, case depth, inclusions, porosity) for automatic rating and reports; motorised stage with scanning and stitching for unattended batches.

5. Do not forget accessories: polariser, darkfield, DIC, and a microhardness interface.

6. Room: an anti-vibration bench at 20±3 °C for research stands; keep preparation and microscopy rooms separate to avoid abrasive dust.

SeriesTypeTypical taskRecommended setup
HX-4A / HX-4BUpright metallurgicalRoutine structure, case depth5×/10×/40× + 5 MP camera
HX-G2A / G2BInvertedBatch samples, no re-mountingBrightfield + simple polariser
HX-G3ATrinocular invertedCase depth, rating, reportsCamera + analysis software
HX-G4C / G5AResearch invertedDarkfield/polarised/DICSemi-apochromat + motorised stage
HX-ZG7 / XSZ-146StereoFracture, solder, low-mag locatingZoom + ring light

Common misconceptions: higher magnification is not better (numerical aperture limits resolution, 100× dry is the practical ceiling); ignoring stage travel so large samples do not fit; buying the stand without software and still rating by eye, which kills repeatability.

08

Prüfverfahren

Preparation. Section perpendicular to the feature of interest. Keep hot-mounting below 150 °C for aluminium and quenched parts, or use cold mounting. Grind 320→600→800→1200, removing previous scratches at each step; polish with 3 µm then 1 µm diamond. Etchants: 4% nital for carbon steel (3–8 s), aqua regia or electrolytic for stainless, Keller for aluminium.

Examination. Locate a representative field at 5×/10×, then switch to higher power. Rate grain size to GB/T 6394 by comparison or intercept. Measure case depth at 500× with an ocular scale or calibrated software, averaging five readings.

Calibration. Verify µm/pixel daily with a stage micrometer, check against a certified specimen quarterly, record three fields per sample and archive images with scale bars.

Pitfalls. Over-etching widens boundaries and fakes decarburisation; residual scratches can be mistaken for cracks; rounded mounting edges inflate case depth. Keep an unetched specimen for coating and crack review.

09

Industry applications

  • Steel and heat treatment: decarburised depth, carburised/nitrided case depth, grain size (GB/T 6394), non-metallic inclusions (GB/T 10561), banding and Widmanstätten rating.
  • Non-ferrous metals: aluminium grain and recrystallisation, alpha/beta ratio in brass, twinning and corrosion morphology in magnesium.
  • Welding and brazing: penetration, HAZ width, porosity and cracks, intermetallic thickness at dissimilar joints.
  • Additive manufacturing: porosity, lack-of-fusion defects, melt-pool morphology in SLM parts, porosity repeatability within 0.2%.
  • Bearings and gears: martensite rating, retained austenite, carbide network and banding, grinding burn and white layer.
  • Electronics: IMC thickness, plating cross-sections, PCB micro-sections, gold wire ball bonds (stereo plus metallurgical).
  • Powders and ceramics: particle morphology and size, sintered porosity, coating cross-section thickness.
  • Failure analysis: fracture surface macro and micro morphology, corrosion products, crack path and origin, with stereo microscopy for low-magnification locating.
10

Price and lead time for this model

By submitting you agree to our privacy policy.

⇄0VergleichTechnischer Vergleich