HOT
BID-500 · 2026-11-17 · +86 21 5748 2007
BID-500 Biological Microscope
Biological Microscope
- 光学放大倍数100X~400X
- 机械筒长∞
- 物镜共轭距离∞
- 目镜大视野WF10X(Φ22mm)、对中目镜
By submitting you agree to our privacy policy.
Überblick
BID-500倒置生物显微镜采用优良的无限远光学系统,可提供出色的光学性能。流线型的设计理念,紧凑稳定的高刚性主体,充分体现了显微操作的防振要求。超长工作距离聚光系统可对高培养皿或圆筒状烧瓶进行无沾染培养细胞观察,照明系统充分考虑散热性与安全性,人机工程学设计理念,使操作更方便舒适安全,空间更广阔。相衬装置可附加在光路中,以实现相衬显微观察。本仪器可对细胞组织,透明液态组织进行显微观察,也可对培养皿中的培养组织进行动态显微观察,可应用于科研院所、高等院校、医疗卫生、检验检疫、农牧乳业等部门。
一、性能特点:
1、铰链式双目观察镜筒,镜筒45度倾斜,双瞳调节范围达48~75mm;
2、低手位移动式机械载物台,可拆卸式机械移动载物装置满足不同高度培养皿的观察;
3、配备三种不同培养皿托板,适用于不同培养皿观察;
4、内置式卤素透射照明系统不仅能对明视场进行观察,还能对相衬观察法进行观察;
5、大视野目镜,视场范围直径22mm;
6、超长工作距离聚光镜,可对高培养皿或圆筒状烧瓶进行无沾染培养细胞观察;
7、在聚光镜插槽内插入相衬插板,根据所使用相衬物镜,将匹配的相衬环推入光路,即可进行相衬观察。
二、技术参数:
光学放大倍数:100X~400X;
机械筒长:∞;
物镜共轭距离:∞;
目镜:大视野WF10X(Φ22mm)、对中目镜;
目镜:铰链双目,观察角度为45度,瞳距为48~75mm,眼点高度高于台面400mm;
目镜接口:Ф30mm;
齐焦距离:10mm;
明场物镜(盖玻片厚度1.2mm):10X/0.25\工作距离4.27mm,20X/0.4\8.0mm,40X/0.6\3.5mm;
相衬物镜PHP2(盖玻片厚度1.2mm):10X/0.25\工作距离4.27mm;
转换器:五孔转换器;
调焦机构:粗微动同轴, 微动格值:2μ, 粗动松紧可调,带锁紧和限位装置,有效调焦行程11mm;
长工作距离聚光镜:长工作距离聚光镜,工作距离70mm,带插板式相衬装置;
载物台:224*208mm;移动范围112*79mm,移动尺可拆卸;
培养皿托板一:86mm(宽)X129.5mm(长),可适配圆形培养皿Ф87.5mm;
培养皿托板二:34mm(宽)X77.5mm(长),可适配圆形培养皿Ф68.5mm;
培养皿托板三:57mm(宽)X82mm(长);
相位相衬系统:拉板式相衬聚光镜,相衬环中心可调;
光源:9W/LED,亮度可调;
滤色片:磨砂玻璃、蓝滤色片;
调校工具:M4、M5内六角扳手;
BID-500 Biological Microscope supplied by CHWES. 19 key specifications available on request.
Technische Daten
| 光学放大倍数 | 100X~400X |
|---|---|
| 机械筒长 | ∞ |
| 物镜共轭距离 | ∞ |
| 目镜 | 大视野WF10X(Φ22mm)、对中目镜 |
| 目镜接口 | Ф30mm |
| 齐焦距离 | 10mm |
| 明场物镜(盖玻片厚度1.2mm) | 10X/0.25\工作距离4.27mm,20X/0.4\8.0mm,40X/0.6\3.5mm |
| 相衬物镜PHP2(盖玻片厚度1.2mm) | 10X/0.25\工作距离4.27mm |
| 转换器 | 五孔转换器 |
| 调焦机构 | 粗微动同轴, 微动格值:2μ, 粗动松紧可调,带锁紧和限位装置,有效调焦行程11mm |
| 长工作距离聚光镜 | 长工作距离聚光镜,工作距离70mm,带插板式相衬装置 |
| 载物台 | 224*208mm;移动范围112*79mm,移动尺可拆卸 |
| 培养皿托板一 | 86mm(宽)X129.5mm(长),可适配圆形培养皿Ф87.5mm |
| 培养皿托板二 | 34mm(宽)X77.5mm(长),可适配圆形培养皿Ф68.5mm |
| 培养皿托板三 | 57mm(宽)X82mm(长) |
| 相位相衬系统 | 拉板式相衬聚光镜,相衬环中心可调 |
| 光源 | 9W/LED,亮度可调 |
| 滤色片 | 磨砂玻璃、蓝滤色片 |
| 调校工具 | M;M5内六角扳手 |
* Generated by rule engine over the product database; for pre-selection only.
Messprinzip
The metallurgical microscope uses an infinity-corrected optical path with reflected Köhler illumination. Light passes the collector, field stop and aperture stop, is deflected by a semi-transparent mirror through the objective onto the specimen, and returns through the same objective to the eyepiece or camera.
- Bright field for routine microstructure, inclusions and decarburised layers.
- Dark field collects scattered light to reveal grain boundaries, cracks and non-metallic inclusions.
- Polarised light identifies anisotropic phases, spheroidised structures and coating stress.
- DIC converts tiny height differences into contrast, ideal for polished, unetched samples.
Objectives of 5× to 100× are combined with 10× eyepieces. Higher numerical aperture gives better resolution but shallower depth of field.
Process animation
- Sampling and preparation: sectioning, mounting, grinding, polishing, etching.
- Illumination and focus: select BF/DF/POL/DIC and focus.
- Image capture: trinocular port, 1× camera adapter, white balance.
- Scale calibration: calibrate µm per pixel with a stage micrometer.
- Measurement: grain size, case depth, coating thickness, inclusion rating.
Calculation & formulas
1. System magnification: M = objective × eyepiece × adapter, e.g. 40× / 10× / 1× = 400×.
2. Resolution: d = 0.61λ/NA (λ≈550 nm). A 40× objective with NA 0.65 resolves 0.52 µm; an NA 0.95 dry objective reaches 0.35 µm.
3. Depth of field scales with λ/NA² — higher NA, shallower depth; use low NA for fracture surfaces.
4. Grain size (GB/T 6394): at 100×, grains N per 645 mm² field follow N = 2G−1; counting 128 grains gives G = log2128 + 1 = 8. Intercept method: mean intercept L̄ = line length ÷ intercepts, G = −6.6437 lg L̄ (mm, 100×).
5. Effective case depth: distance to 550 HV1, fitted from a micro-hardness traverse and averaged over three positions.
Normen
| Standard | Title | Scope |
|---|---|---|
| GB/T 13298-2015 | Metallic materials — examination of microstructure | Microstructure rating |
| GB/T 6394-2017 | Determination of average grain size | Grain size |
| ASTM E3-11 | Guide for metallographic specimen preparation | Preparation |
| ASTM E112 | Determining average grain size | Grain size |
| ISO 643 | Steels — micrographic determination of grain size | Grain size |
Export projects often require dual GB and ASTM reports; the software ships both rating charts.
Auswahl
1. Surface or cross-section: stereo microscopes (HX-ZG7, XSZ) for fracture surfaces, solder joints and coatings; upright or inverted metallurgical microscopes (HX-4, HX-G series) for microstructure, case depth and inclusions.
2. Upright or inverted: upright for small specimens that are flipped often; inverted (HX-G3A/G4C/G5A) for large, heavy parts such as gears, shafts and tube sections that go straight onto the stage without re-mounting.
3. Optics set the ceiling: plan achromats cover routine rating; semi-apochromats or apochromats with a research stand (HX-G5A) are needed for 1000× precipitates and brightfield/darkfield/polarised switching.
4. Three levels of digitalisation: a 5 MP camera for images; camera plus analysis software (grain size, case depth, inclusions, porosity) for automatic rating and reports; motorised stage with scanning and stitching for unattended batches.
5. Do not forget accessories: polariser, darkfield, DIC, and a microhardness interface.
6. Room: an anti-vibration bench at 20±3 °C for research stands; keep preparation and microscopy rooms separate to avoid abrasive dust.
| Series | Type | Typical task | Recommended setup |
|---|---|---|---|
| HX-4A / HX-4B | Upright metallurgical | Routine structure, case depth | 5×/10×/40× + 5 MP camera |
| HX-G2A / G2B | Inverted | Batch samples, no re-mounting | Brightfield + simple polariser |
| HX-G3A | Trinocular inverted | Case depth, rating, reports | Camera + analysis software |
| HX-G4C / G5A | Research inverted | Darkfield/polarised/DIC | Semi-apochromat + motorised stage |
| HX-ZG7 / XSZ-146 | Stereo | Fracture, solder, low-mag locating | Zoom + ring light |
Common misconceptions: higher magnification is not better (numerical aperture limits resolution, 100× dry is the practical ceiling); ignoring stage travel so large samples do not fit; buying the stand without software and still rating by eye, which kills repeatability.
Prüfverfahren
Preparation. Section perpendicular to the feature of interest. Keep hot-mounting below 150 °C for aluminium and quenched parts, or use cold mounting. Grind 320→600→800→1200, removing previous scratches at each step; polish with 3 µm then 1 µm diamond. Etchants: 4% nital for carbon steel (3–8 s), aqua regia or electrolytic for stainless, Keller for aluminium.
Examination. Locate a representative field at 5×/10×, then switch to higher power. Rate grain size to GB/T 6394 by comparison or intercept. Measure case depth at 500× with an ocular scale or calibrated software, averaging five readings.
Calibration. Verify µm/pixel daily with a stage micrometer, check against a certified specimen quarterly, record three fields per sample and archive images with scale bars.
Pitfalls. Over-etching widens boundaries and fakes decarburisation; residual scratches can be mistaken for cracks; rounded mounting edges inflate case depth. Keep an unetched specimen for coating and crack review.
Industry applications
- Steel and heat treatment: decarburised depth, carburised/nitrided case depth, grain size (GB/T 6394), non-metallic inclusions (GB/T 10561), banding and Widmanstätten rating.
- Non-ferrous metals: aluminium grain and recrystallisation, alpha/beta ratio in brass, twinning and corrosion morphology in magnesium.
- Welding and brazing: penetration, HAZ width, porosity and cracks, intermetallic thickness at dissimilar joints.
- Additive manufacturing: porosity, lack-of-fusion defects, melt-pool morphology in SLM parts, porosity repeatability within 0.2%.
- Bearings and gears: martensite rating, retained austenite, carbide network and banding, grinding burn and white layer.
- Electronics: IMC thickness, plating cross-sections, PCB micro-sections, gold wire ball bonds (stereo plus metallurgical).
- Powders and ceramics: particle morphology and size, sintered porosity, coating cross-section thickness.
- Failure analysis: fracture surface macro and micro morphology, corrosion products, crack path and origin, with stereo microscopy for low-magnification locating.