BID-300 Biological Microscope

Biological Microscope

ModellBID-300
  • 光学放大倍数100X~400X
  • 物镜共轭距离∞
  • 目镜接口直径30mm
  • 齐焦距离10mm

By submitting you agree to our privacy policy.

01

Überblick

BID-300倒置生物显微镜采用优良的无限远光学系统。配置长工作距离平场物镜与大视野目镜,紧凑稳定的高刚性主体,充分体现了显微操作的防振要求。旋转摆入摆出式聚光系统,可对高培养皿或圆筒状烧瓶进行无沾染培养细胞观察。符合人机工程学要求的理想设计,使操作更方便舒适,空间更广阔。本仪器适用于对细胞组织,透明液态组织的显微观察,也可对培养皿中的培养组织进行动态显微观察。可应用于科研院所、高等院校、医疗卫生、检验检疫、农牧乳业等部门。
一、性能特点:
1、铰链式双目观察镜筒,镜筒45度倾斜;
2、高品质透明玻璃载物台板,很好降低载物台受热变形影像,物镜转换过程清晰可见;
3、高强度同轴挠性钢丝传动,极限位置自动保护功能,配备三种不同培养皿托板,适用于不同培养皿观察;
4、一体化照明系统,同时配备旋转式聚光系统,科迪高培养皿或圆筒状烧瓶进行无沾染培养细胞观察;
5、大视野目镜,视场范围直径22mm;
6、高品质相衬平场物镜与相衬聚光镜,拉板式和转盘式两种类型;
7、后置式摄影摄像接口设计,摄影摄像不干扰目镜观察;100%通光适合低照度的显微摄影摄像。
二、技术参数:
光学放大倍数:100X~400X;
物镜共轭距离:∞;
目镜接口:直径30mm;
齐焦距离:10mm;
目镜:大视野WF10X(Φ22mm)、对中望远镜;
无限远长距平场消色差物镜PLL(盖玻片厚度1.2mm):10X/0.25\工作距离19.4mm,20X/0.4\8.0mm,40X/0.6\3.5mm;
无限远长距平场消色差相衬物镜PHP(盖玻片厚度1.2mm):10X/0.25\工作距离4.3mm;
目镜筒:三目镜(倾斜45度),瞳距53~75mm;
调焦机构:粗微动同轴调焦, 粗动松紧可调,带锁紧和限位装置,微动格值:2μm;
转换器:五孔;
载物台:双层机械移动式,227*208mm,移动范围:134.5mmX77mm,移动尺可拆卸;
载物台台板:玻璃圆载物台板尺寸Ф118mm;
载物台培养皿托板一:86mm(宽)X129.5mm(长),可适配圆形培养皿Ф87.5mm;
载物台培养皿托板二:34mm(宽)X77.5mm(长),可适配圆形培养皿Ф68.5mm;
载物台培养皿托板三:57mm(宽)X82mm(长);
聚光系统:特长工作距离聚光镜,工作距离55mm,带转盘式相衬装置;
照明系统:6V30W卤素灯,亮度与空间位置可调;
滤色片:蓝滤色片、绿滤色片、磨砂玻璃;
三、选配配件:
1、目镜:分划10X(Φ22mm),格值0.1mm/格;
2、相衬物镜:PLL20/0.40 PHP2 工作距离:8.0mm;
3、相衬物镜:PLL40/0.65 PHP2 工作距离:3.5mm;
4、样本适配器:
孔座最大直径50.5mm,中心距离63mm,适配外径50mm培养皿观察;
孔座最大35.5mm,适配外径35mm培养皿观察;
孔座最大尺寸51.5X74.5mm,适配T25型培养皿观察;
孔座最大尺寸66.5X66.5mm,适配66X66mm方形培养皿观察;
孔座最大尺寸76.6X26.2mm,适配标准载玻片样品观察;
5、滤色片:黄滤色片;
6、聚光镜:超长工作距离,带滤色片座,工作距离:70mm;
7、相衬装置:转盘式相衬装置;

BID-300 Biological Microscope supplied by CHWES. 16 key specifications available on request.

02

Technische Daten

光学放大倍数100X~400X
物镜共轭距离∞
目镜接口直径30mm
齐焦距离10mm
目镜大视野WF10X(Φ22mm)、对中望远镜;无限远长距平场消色差物镜PLL(盖玻片厚度1.2mm):10X/0.25\工作距离19.4mm,20X/0.4\8.0mm,40X/0.6\3.5mm
目镜筒三目镜(倾斜45度),瞳距53~75mm
调焦机构粗微动同轴调焦, 粗动松紧可调,带锁紧和限位装置,微动格值:2μm
转换器五孔
载物台双层机械移动式,227*208mm,移动范围:134.5mmX77mm,移动尺可拆卸
载物台台板玻璃圆载物台板尺寸Ф118mm
载物台培养皿托板一86mm(宽)X129.5mm(长),可适配圆形培养皿Ф87.5mm
载物台培养皿托板二34mm(宽)X77.5mm(长),可适配圆形培养皿Ф68.5mm
载物台培养皿托板三57mm(宽)X82mm(长)
聚光系统特长工作距离聚光镜,工作距离55mm,带转盘式相衬装置
照明系统6V30W卤素灯,亮度与空间位置可调
滤色片蓝滤色片、绿滤色片、磨砂玻璃

* Generated by rule engine over the product database; for pre-selection only.

03

Messprinzip

The metallurgical microscope uses an infinity-corrected optical path with reflected Köhler illumination. Light passes the collector, field stop and aperture stop, is deflected by a semi-transparent mirror through the objective onto the specimen, and returns through the same objective to the eyepiece or camera.

  • Bright field for routine microstructure, inclusions and decarburised layers.
  • Dark field collects scattered light to reveal grain boundaries, cracks and non-metallic inclusions.
  • Polarised light identifies anisotropic phases, spheroidised structures and coating stress.
  • DIC converts tiny height differences into contrast, ideal for polished, unetched samples.

Objectives of 5× to 100× are combined with 10× eyepieces. Higher numerical aperture gives better resolution but shallower depth of field.

04

Process animation

  1. Sampling and preparation: sectioning, mounting, grinding, polishing, etching.
  2. Illumination and focus: select BF/DF/POL/DIC and focus.
  3. Image capture: trinocular port, 1× camera adapter, white balance.
  4. Scale calibration: calibrate µm per pixel with a stage micrometer.
  5. Measurement: grain size, case depth, coating thickness, inclusion rating.
0102030405
05

Calculation & formulas

1. System magnification: M = objective × eyepiece × adapter, e.g. 40× / 10× / 1× = 400×.

2. Resolution: d = 0.61λ/NA (λ≈550 nm). A 40× objective with NA 0.65 resolves 0.52 µm; an NA 0.95 dry objective reaches 0.35 µm.

3. Depth of field scales with λ/NA² — higher NA, shallower depth; use low NA for fracture surfaces.

4. Grain size (GB/T 6394): at 100×, grains N per 645 mm² field follow N = 2G−1; counting 128 grains gives G = log2128 + 1 = 8. Intercept method: mean intercept L̄ = line length ÷ intercepts, G = −6.6437 lg L̄ (mm, 100×).

5. Effective case depth: distance to 550 HV1, fitted from a micro-hardness traverse and averaged over three positions.

06

Normen

StandardTitleScope
GB/T 13298-2015Metallic materials — examination of microstructureMicrostructure rating
GB/T 6394-2017Determination of average grain sizeGrain size
ASTM E3-11Guide for metallographic specimen preparationPreparation
ASTM E112Determining average grain sizeGrain size
ISO 643Steels — micrographic determination of grain sizeGrain size

Export projects often require dual GB and ASTM reports; the software ships both rating charts.

07

Auswahl

1. Surface or cross-section: stereo microscopes (HX-ZG7, XSZ) for fracture surfaces, solder joints and coatings; upright or inverted metallurgical microscopes (HX-4, HX-G series) for microstructure, case depth and inclusions.

2. Upright or inverted: upright for small specimens that are flipped often; inverted (HX-G3A/G4C/G5A) for large, heavy parts such as gears, shafts and tube sections that go straight onto the stage without re-mounting.

3. Optics set the ceiling: plan achromats cover routine rating; semi-apochromats or apochromats with a research stand (HX-G5A) are needed for 1000× precipitates and brightfield/darkfield/polarised switching.

4. Three levels of digitalisation: a 5 MP camera for images; camera plus analysis software (grain size, case depth, inclusions, porosity) for automatic rating and reports; motorised stage with scanning and stitching for unattended batches.

5. Do not forget accessories: polariser, darkfield, DIC, and a microhardness interface.

6. Room: an anti-vibration bench at 20±3 °C for research stands; keep preparation and microscopy rooms separate to avoid abrasive dust.

SeriesTypeTypical taskRecommended setup
HX-4A / HX-4BUpright metallurgicalRoutine structure, case depth5×/10×/40× + 5 MP camera
HX-G2A / G2BInvertedBatch samples, no re-mountingBrightfield + simple polariser
HX-G3ATrinocular invertedCase depth, rating, reportsCamera + analysis software
HX-G4C / G5AResearch invertedDarkfield/polarised/DICSemi-apochromat + motorised stage
HX-ZG7 / XSZ-146StereoFracture, solder, low-mag locatingZoom + ring light

Common misconceptions: higher magnification is not better (numerical aperture limits resolution, 100× dry is the practical ceiling); ignoring stage travel so large samples do not fit; buying the stand without software and still rating by eye, which kills repeatability.

08

Prüfverfahren

Preparation. Section perpendicular to the feature of interest. Keep hot-mounting below 150 °C for aluminium and quenched parts, or use cold mounting. Grind 320→600→800→1200, removing previous scratches at each step; polish with 3 µm then 1 µm diamond. Etchants: 4% nital for carbon steel (3–8 s), aqua regia or electrolytic for stainless, Keller for aluminium.

Examination. Locate a representative field at 5×/10×, then switch to higher power. Rate grain size to GB/T 6394 by comparison or intercept. Measure case depth at 500× with an ocular scale or calibrated software, averaging five readings.

Calibration. Verify µm/pixel daily with a stage micrometer, check against a certified specimen quarterly, record three fields per sample and archive images with scale bars.

Pitfalls. Over-etching widens boundaries and fakes decarburisation; residual scratches can be mistaken for cracks; rounded mounting edges inflate case depth. Keep an unetched specimen for coating and crack review.

09

Industry applications

  • Steel and heat treatment: decarburised depth, carburised/nitrided case depth, grain size (GB/T 6394), non-metallic inclusions (GB/T 10561), banding and Widmanstätten rating.
  • Non-ferrous metals: aluminium grain and recrystallisation, alpha/beta ratio in brass, twinning and corrosion morphology in magnesium.
  • Welding and brazing: penetration, HAZ width, porosity and cracks, intermetallic thickness at dissimilar joints.
  • Additive manufacturing: porosity, lack-of-fusion defects, melt-pool morphology in SLM parts, porosity repeatability within 0.2%.
  • Bearings and gears: martensite rating, retained austenite, carbide network and banding, grinding burn and white layer.
  • Electronics: IMC thickness, plating cross-sections, PCB micro-sections, gold wire ball bonds (stereo plus metallurgical).
  • Powders and ceramics: particle morphology and size, sintered porosity, coating cross-section thickness.
  • Failure analysis: fracture surface macro and micro morphology, corrosion products, crack path and origin, with stereo microscopy for low-magnification locating.
10

Price and lead time for this model

By submitting you agree to our privacy policy.

⇄0VergleichTechnischer Vergleich