Positioning repeatability of BIW welding slides degraded over time, pushing side-panel weld spot deviation beyond 0.5 mm; line-stopping teardown was costly.
Solution: the MC030-WF200-5700 wireless autocollimator (±5700 arcsec range) mounts the mirror during cycle gaps and measures the 8 m slide every 400 mm, producing a straightness curve within 30 minutes for trend comparison.
Result: 2 of 6 slides exceeded tolerance (max 0.12 mm/8 m in the vertical plane). After targeted shimming, weld spot deviation returned within 0.2 mm with zero line downtime.