ICP-OES monitoring of Cr(VI) reduction effluent

An ICPS-7510 auto-samples every 30 minutes for total Cr, Ni and Zn, interlocking discharge on exceedance — a full year within limits.

회사명
Electroplating park WWTP, PRD
주소
Shenzhen, Guangdong
ICP-OES monitoring of Cr(VI) reduction effluent
17,520Data sets per year
≤30 minFailure detection

Multiple plating lines share the WWTP, and twice-daily manual sampling missed reduction-bath failures.

Solution: ICPS-7510 with autosampler and on-line filtration runs total Cr/Ni/Zn every 30 minutes; exceedances interlock a recirculation valve to block discharge and alarm.

Result: 17,520 data sets within limits all year; three bath failures caught within 30 minutes instead of ~6 hours, dosing costs down 18%, and a clean environmental-credit review.