Engines2024

Bore roundness, cylindricity and waviness diagnose oil consumption

Y9025C measured three sections and ran a waviness spectrum, identifying sixth-order waviness from an unbalanced honing head; oil consumption fell 35% after correction.

Company
Diesel engine plant, Anhui
Address
Hefei, Anhui
Bore roundness, cylindricity and waviness diagnose oil consumption
3.2 → 1.1 μm6th-order amplitude
-35%Oil consumption
6.5 μmRoundness

A diesel batch showed high oil consumption (0.3% of fuel or more). Teardown revealed uniform axial striations on the bore, pointing to honing, but a roundness-only check gave no explanation.

Solution: Y9025C measuring roundness and cylindricity at top, middle and bottom sections with harmonic analysis of the circumference from order 2 to 50, plus Ra and Rz to judge the cross-hatch.

Result: roundness of 6.5 µm was acceptable, but sixth-order amplitude reached 3.2 µm against a 1.5 µm limit, matching imbalance in the six-stone honing head; after replacement and balancing it fell to 1.1 µm and oil consumption dropped 35%, now a routine honing monitor.

⇄0CompareProduct comparison