  • 光学放大倍数40~1000X、40~600X
  • 目镜大视野WF10X(Φ18mm)、分划目镜10X (Φ18mm),0.10mm/格;PM-12A无应力平场消色差物镜(盖玻片0.17mm)PL/POL:4X/0.10\17.94工作距离、10X/0.25\8.
  • 目镜筒三目镜,倾斜30度,可进行100%透光摄影
  • 透射照明可360度旋转起偏器、有;1;270四个读数,卤素灯照明适用的带视场光栏集光器,光源6V20W卤素灯亮度可调,N.A.1.25可上下升降的阿贝聚光镜、带可变光栏

By submitting you agree to our privacy policy.

01

Overview

PM-12透射偏光显微镜是利用光的偏振特性对具有双折射性物质进行研究鉴定的必备仪器,可供广大用户进行透射单偏光观察,正交偏光观察,锥光观察。广泛应用于地质、化工、医疗、药品等领域的研究与检验,也可进行液态高分子材料,生物聚合物及液晶材料的晶相观察,是科研机构与高等院校进行研究与教学的理想仪器。
一、技术特点:
铰链式三目观察镜筒、单视度可调;
二、技术参数:
光学放大倍数:40~1000X、40~600X;
目镜:大视野WF10X(Φ18mm)、分划目镜10X (Φ18mm),0.10mm/格;
PM-12A无应力平场消色差物镜(盖玻片0.17mm)PL/POL:4X/0.10\17.94工作距离、10X/0.25\8.8、40X/0.65\0.56(弹簧)、100X/1.25\0.36(弹簧、油);
PM-12B无应力平场消色差物镜(无盖玻片)PLLPOL:4X/0.12/17.9工作距离、10X/0.25\8.8、40X/0.60\3.73(弹簧)、60X/0.75\1.34(弹簧);
目镜筒:三目镜,倾斜30度,可进行100%透光摄影;
透射照明:可360度旋转起偏器、有0、90、180、270四个读数,卤素灯照明适用的带视场光栏集光器,光源6V20W卤素灯亮度可调,N.A.1.25可上下升降的阿贝聚光镜、带可变光栏;
调焦机构:粗微动同轴调焦, 微动格值:2μm,带锁紧和限位装置;
转换器:四孔(物镜中心位置可调);
载物台:旋转式载物台,直径:Φ150mm,360度等分刻度,游标格值6',中心可调,带锁紧装置;
中间接筒:带刻度和游标的内置推入式检偏器, 可自由切换正常观察与偏光观察,90°旋转,游标格值12';
中间接筒:推入式勃氏镜,中心可调;
中间接筒:λ补偿器;
中间接筒:λ/4补偿器;
中间接筒:石英锲补偿器;
三、选配件:
1、目镜:大视野WF16X(Φ11mm);
2、无应力平场消色差物镜(中心可调、盖玻片0.17mm)PL:20X/0.40、60X/0.75;
3、无应力平场消色差物镜(中心可调、无盖玻片)PLL:20X/0.40、50X/0.70、80X/0.80、100X/0.85(弹簧、干式);
4、移动尺:移动范围30*25mm;
5、摄影接口:USB/VIDEO;
6、数码相机接口;
7、CCD适配镜:0.4X/0.5X/1X/0.5X带分划;

PM-12 Polarizing Microscope (透射) supplied by CHWES. 8 key specifications available on request.

02

Specifications

光学放大倍数40~1000X、40~600X
目镜大视野WF10X(Φ18mm)、分划目镜10X (Φ18mm),0.10mm/格;PM-12A无应力平场消色差物镜(盖玻片0.17mm)PL/POL:4X/0.10\17.94工作距离、10X/0.25\8.
目镜筒三目镜,倾斜30度,可进行100%透光摄影
透射照明可360度旋转起偏器、有;1;270四个读数,卤素灯照明适用的带视场光栏集光器,光源6V20W卤素灯亮度可调,N.A.1.25可上下升降的阿贝聚光镜、带可变光栏
调焦机构粗微动同轴调焦, 微动格值:2μm,带锁紧和限位装置
转换器四孔(物镜中心位置可调)
载物台旋转式载物台,直径:Φ150mm,360度等分刻度,游标格值6',中心可调,带锁紧装置
中间接筒带刻度和游标的内置推入式检偏器, 可自由切换正常观察与偏光观察,90°旋转,游标格值12'

* Generated by rule engine over the product database; for pre-selection only.

03

Working principle

The metallurgical microscope uses an infinity-corrected optical path with reflected Köhler illumination. Light passes the collector, field stop and aperture stop, is deflected by a semi-transparent mirror through the objective onto the specimen, and returns through the same objective to the eyepiece or camera.

  • Bright field for routine microstructure, inclusions and decarburised layers.
  • Dark field collects scattered light to reveal grain boundaries, cracks and non-metallic inclusions.
  • Polarised light identifies anisotropic phases, spheroidised structures and coating stress.
  • DIC converts tiny height differences into contrast, ideal for polished, unetched samples.

Objectives of 5× to 100× are combined with 10× eyepieces. Higher numerical aperture gives better resolution but shallower depth of field.

04

Process animation

  1. Sampling and preparation: sectioning, mounting, grinding, polishing, etching.
  2. Illumination and focus: select BF/DF/POL/DIC and focus.
  3. Image capture: trinocular port, 1× camera adapter, white balance.
  4. Scale calibration: calibrate µm per pixel with a stage micrometer.
  5. Measurement: grain size, case depth, coating thickness, inclusion rating.
0102030405
05

Calculation & formulas

1. System magnification: M = objective × eyepiece × adapter, e.g. 40× / 10× / 1× = 400×.

2. Resolution: d = 0.61λ/NA (λ≈550 nm). A 40× objective with NA 0.65 resolves 0.52 µm; an NA 0.95 dry objective reaches 0.35 µm.

3. Depth of field scales with λ/NA² — higher NA, shallower depth; use low NA for fracture surfaces.

4. Grain size (GB/T 6394): at 100×, grains N per 645 mm² field follow N = 2G−1; counting 128 grains gives G = log2128 + 1 = 8. Intercept method: mean intercept L̄ = line length ÷ intercepts, G = −6.6437 lg L̄ (mm, 100×).

5. Effective case depth: distance to 550 HV1, fitted from a micro-hardness traverse and averaged over three positions.

06

Standards

StandardTitleScope
GB/T 13298-2015Metallic materials — examination of microstructureMicrostructure rating
GB/T 6394-2017Determination of average grain sizeGrain size
ASTM E3-11Guide for metallographic specimen preparationPreparation
ASTM E112Determining average grain sizeGrain size
ISO 643Steels — micrographic determination of grain sizeGrain size

Export projects often require dual GB and ASTM reports; the software ships both rating charts.

07

Selection guide

1. Surface or cross-section: stereo microscopes (HX-ZG7, XSZ) for fracture surfaces, solder joints and coatings; upright or inverted metallurgical microscopes (HX-4, HX-G series) for microstructure, case depth and inclusions.

2. Upright or inverted: upright for small specimens that are flipped often; inverted (HX-G3A/G4C/G5A) for large, heavy parts such as gears, shafts and tube sections that go straight onto the stage without re-mounting.

3. Optics set the ceiling: plan achromats cover routine rating; semi-apochromats or apochromats with a research stand (HX-G5A) are needed for 1000× precipitates and brightfield/darkfield/polarised switching.

4. Three levels of digitalisation: a 5 MP camera for images; camera plus analysis software (grain size, case depth, inclusions, porosity) for automatic rating and reports; motorised stage with scanning and stitching for unattended batches.

5. Do not forget accessories: polariser, darkfield, DIC, and a microhardness interface.

6. Room: an anti-vibration bench at 20±3 °C for research stands; keep preparation and microscopy rooms separate to avoid abrasive dust.

SeriesTypeTypical taskRecommended setup
HX-4A / HX-4BUpright metallurgicalRoutine structure, case depth5×/10×/40× + 5 MP camera
HX-G2A / G2BInvertedBatch samples, no re-mountingBrightfield + simple polariser
HX-G3ATrinocular invertedCase depth, rating, reportsCamera + analysis software
HX-G4C / G5AResearch invertedDarkfield/polarised/DICSemi-apochromat + motorised stage
HX-ZG7 / XSZ-146StereoFracture, solder, low-mag locatingZoom + ring light

Common misconceptions: higher magnification is not better (numerical aperture limits resolution, 100× dry is the practical ceiling); ignoring stage travel so large samples do not fit; buying the stand without software and still rating by eye, which kills repeatability.

08

Test method

Preparation. Section perpendicular to the feature of interest. Keep hot-mounting below 150 °C for aluminium and quenched parts, or use cold mounting. Grind 320→600→800→1200, removing previous scratches at each step; polish with 3 µm then 1 µm diamond. Etchants: 4% nital for carbon steel (3–8 s), aqua regia or electrolytic for stainless, Keller for aluminium.

Examination. Locate a representative field at 5×/10×, then switch to higher power. Rate grain size to GB/T 6394 by comparison or intercept. Measure case depth at 500× with an ocular scale or calibrated software, averaging five readings.

Calibration. Verify µm/pixel daily with a stage micrometer, check against a certified specimen quarterly, record three fields per sample and archive images with scale bars.

Pitfalls. Over-etching widens boundaries and fakes decarburisation; residual scratches can be mistaken for cracks; rounded mounting edges inflate case depth. Keep an unetched specimen for coating and crack review.

09

Industry applications

  • Steel and heat treatment: decarburised depth, carburised/nitrided case depth, grain size (GB/T 6394), non-metallic inclusions (GB/T 10561), banding and Widmanstätten rating.
  • Non-ferrous metals: aluminium grain and recrystallisation, alpha/beta ratio in brass, twinning and corrosion morphology in magnesium.
  • Welding and brazing: penetration, HAZ width, porosity and cracks, intermetallic thickness at dissimilar joints.
  • Additive manufacturing: porosity, lack-of-fusion defects, melt-pool morphology in SLM parts, porosity repeatability within 0.2%.
  • Bearings and gears: martensite rating, retained austenite, carbide network and banding, grinding burn and white layer.
  • Electronics: IMC thickness, plating cross-sections, PCB micro-sections, gold wire ball bonds (stereo plus metallurgical).
  • Powders and ceramics: particle morphology and size, sintered porosity, coating cross-section thickness.
  • Failure analysis: fracture surface macro and micro morphology, corrosion products, crack path and origin, with stereo microscopy for low-magnification locating.
10

Price and lead time for this model

By submitting you agree to our privacy policy.

⇄0CompareProduct comparison