HOT
PM-10 · 2026-11-17 · +86 21 5748 2007
PM-10 Polarizing Microscope
Polarizing Microscope
- 光学放大倍数40~1000X
- 目镜大视野 WF10X(Φ18mm)
- 消色差物镜4X/0.;10X/0.;40X/0.65(弹簧)、100X/1.25(弹簧、油)
- 目镜筒双目镜,倾斜30度
By submitting you agree to our privacy policy.
Overview
PM-10正置偏光显微镜是利用光的偏振特性对具有双折射性物质进行研究鉴定的必备仪器。它在医学上有广泛的用途,如观察齿、骨、头发、及活细胞等的结晶内含物、神经纤维、动物肌肉、植物纤维等的结构细节,分析变性过程。也可以观察无机化学中各种盐类的结晶状况在自然光看不到的精细结构。
一、技术特点:
1、配置大视野目镜和消色差物镜,视场大而且清晰;
2、粗微动同轴调焦机构,粗动松紧可调,带限位锁紧装置,微动格值:2μm;
3、6V20W卤素灯透射照明,亮度可调;
二、技术参数:
光学放大倍数:40~1000X;
目镜:大视野 WF10X(Φ18mm);
消色差物镜:4X/0.10、10X/0.25、40X/0.65(弹簧)、100X/1.25(弹簧、油);
目镜筒:双目镜,倾斜30度;
检偏器:推拉式;
调焦机构:粗微动同轴调焦, 微动格值:2μm,带锁紧和限位装置;
转换器:四孔(内向式滚珠内定位);
PM-10载物台:旋转式载物台(直径:Φ120mm);
PM-10A载物台:双层机械移动式载物台附加(Φ100mm)旋转式载物台(尺寸:135mmX125mm、移动范围:75mmX35mm);
阿贝聚光镜:NA.1.25、可上下升降;
滤色片:蓝滤色片、磨砂玻璃;
起偏器:可360度旋转;
集光器:卤素灯照明适用;
照明系统:6V/20W卤素灯,亮度可调;
三、选配件:
1、目镜:大视野WF16X(Φ11mm)或者分划10X(Φ18mm) 格值0.1mm/格;
2、目镜筒:单目镜,可360度旋转,倾斜30度或者三目镜,倾斜30度可同时观察与摄影;
3、转换器:五孔(内向式滚珠内定位);
4、滤色片:绿滤色片、黄滤色片;
5、摄影接口:USB/VIDEO;
6、数码相机接口;
7、CCD适配镜:0.4X/0.5X/1X/0.5X带分划;
PM-10 Polarizing Microscope supplied by CHWES. 14 key specifications available on request.
Specifications
| 光学放大倍数 | 40~1000X |
|---|---|
| 目镜 | 大视野 WF10X(Φ18mm) |
| 消色差物镜 | 4X/0.;10X/0.;40X/0.65(弹簧)、100X/1.25(弹簧、油) |
| 目镜筒 | 双目镜,倾斜30度 |
| 检偏器 | 推拉式 |
| 调焦机构 | 粗微动同轴调焦, 微动格值:2μm,带锁紧和限位装置 |
| 转换器 | 四孔(内向式滚珠内定位) |
| PM-10载物台 | 旋转式载物台(直径:Φ120mm) |
| PM-10A载物台 | 双层机械移动式载物台附加(Φ100mm)旋转式载物台(尺寸:135mmX125mm、移动范围:75mmX35mm) |
| 阿贝聚光镜 | NA.1.;可上下升降 |
| 滤色片 | 蓝滤色片、磨砂玻璃 |
| 起偏器 | 可360度旋转 |
| 集光器 | 卤素灯照明适用 |
| 照明系统 | 6V/20W卤素灯,亮度可调 |
* Generated by rule engine over the product database; for pre-selection only.
Working principle
The metallurgical microscope uses an infinity-corrected optical path with reflected Köhler illumination. Light passes the collector, field stop and aperture stop, is deflected by a semi-transparent mirror through the objective onto the specimen, and returns through the same objective to the eyepiece or camera.
- Bright field for routine microstructure, inclusions and decarburised layers.
- Dark field collects scattered light to reveal grain boundaries, cracks and non-metallic inclusions.
- Polarised light identifies anisotropic phases, spheroidised structures and coating stress.
- DIC converts tiny height differences into contrast, ideal for polished, unetched samples.
Objectives of 5× to 100× are combined with 10× eyepieces. Higher numerical aperture gives better resolution but shallower depth of field.
Process animation
- Sampling and preparation: sectioning, mounting, grinding, polishing, etching.
- Illumination and focus: select BF/DF/POL/DIC and focus.
- Image capture: trinocular port, 1× camera adapter, white balance.
- Scale calibration: calibrate µm per pixel with a stage micrometer.
- Measurement: grain size, case depth, coating thickness, inclusion rating.
Calculation & formulas
1. System magnification: M = objective × eyepiece × adapter, e.g. 40× / 10× / 1× = 400×.
2. Resolution: d = 0.61λ/NA (λ≈550 nm). A 40× objective with NA 0.65 resolves 0.52 µm; an NA 0.95 dry objective reaches 0.35 µm.
3. Depth of field scales with λ/NA² — higher NA, shallower depth; use low NA for fracture surfaces.
4. Grain size (GB/T 6394): at 100×, grains N per 645 mm² field follow N = 2G−1; counting 128 grains gives G = log2128 + 1 = 8. Intercept method: mean intercept L̄ = line length ÷ intercepts, G = −6.6437 lg L̄ (mm, 100×).
5. Effective case depth: distance to 550 HV1, fitted from a micro-hardness traverse and averaged over three positions.
Standards
| Standard | Title | Scope |
|---|---|---|
| GB/T 13298-2015 | Metallic materials — examination of microstructure | Microstructure rating |
| GB/T 6394-2017 | Determination of average grain size | Grain size |
| ASTM E3-11 | Guide for metallographic specimen preparation | Preparation |
| ASTM E112 | Determining average grain size | Grain size |
| ISO 643 | Steels — micrographic determination of grain size | Grain size |
Export projects often require dual GB and ASTM reports; the software ships both rating charts.
Selection guide
1. Surface or cross-section: stereo microscopes (HX-ZG7, XSZ) for fracture surfaces, solder joints and coatings; upright or inverted metallurgical microscopes (HX-4, HX-G series) for microstructure, case depth and inclusions.
2. Upright or inverted: upright for small specimens that are flipped often; inverted (HX-G3A/G4C/G5A) for large, heavy parts such as gears, shafts and tube sections that go straight onto the stage without re-mounting.
3. Optics set the ceiling: plan achromats cover routine rating; semi-apochromats or apochromats with a research stand (HX-G5A) are needed for 1000× precipitates and brightfield/darkfield/polarised switching.
4. Three levels of digitalisation: a 5 MP camera for images; camera plus analysis software (grain size, case depth, inclusions, porosity) for automatic rating and reports; motorised stage with scanning and stitching for unattended batches.
5. Do not forget accessories: polariser, darkfield, DIC, and a microhardness interface.
6. Room: an anti-vibration bench at 20±3 °C for research stands; keep preparation and microscopy rooms separate to avoid abrasive dust.
| Series | Type | Typical task | Recommended setup |
|---|---|---|---|
| HX-4A / HX-4B | Upright metallurgical | Routine structure, case depth | 5×/10×/40× + 5 MP camera |
| HX-G2A / G2B | Inverted | Batch samples, no re-mounting | Brightfield + simple polariser |
| HX-G3A | Trinocular inverted | Case depth, rating, reports | Camera + analysis software |
| HX-G4C / G5A | Research inverted | Darkfield/polarised/DIC | Semi-apochromat + motorised stage |
| HX-ZG7 / XSZ-146 | Stereo | Fracture, solder, low-mag locating | Zoom + ring light |
Common misconceptions: higher magnification is not better (numerical aperture limits resolution, 100× dry is the practical ceiling); ignoring stage travel so large samples do not fit; buying the stand without software and still rating by eye, which kills repeatability.
Test method
Preparation. Section perpendicular to the feature of interest. Keep hot-mounting below 150 °C for aluminium and quenched parts, or use cold mounting. Grind 320→600→800→1200, removing previous scratches at each step; polish with 3 µm then 1 µm diamond. Etchants: 4% nital for carbon steel (3–8 s), aqua regia or electrolytic for stainless, Keller for aluminium.
Examination. Locate a representative field at 5×/10×, then switch to higher power. Rate grain size to GB/T 6394 by comparison or intercept. Measure case depth at 500× with an ocular scale or calibrated software, averaging five readings.
Calibration. Verify µm/pixel daily with a stage micrometer, check against a certified specimen quarterly, record three fields per sample and archive images with scale bars.
Pitfalls. Over-etching widens boundaries and fakes decarburisation; residual scratches can be mistaken for cracks; rounded mounting edges inflate case depth. Keep an unetched specimen for coating and crack review.
Industry applications
- Steel and heat treatment: decarburised depth, carburised/nitrided case depth, grain size (GB/T 6394), non-metallic inclusions (GB/T 10561), banding and Widmanstätten rating.
- Non-ferrous metals: aluminium grain and recrystallisation, alpha/beta ratio in brass, twinning and corrosion morphology in magnesium.
- Welding and brazing: penetration, HAZ width, porosity and cracks, intermetallic thickness at dissimilar joints.
- Additive manufacturing: porosity, lack-of-fusion defects, melt-pool morphology in SLM parts, porosity repeatability within 0.2%.
- Bearings and gears: martensite rating, retained austenite, carbide network and banding, grinding burn and white layer.
- Electronics: IMC thickness, plating cross-sections, PCB micro-sections, gold wire ball bonds (stereo plus metallurgical).
- Powders and ceramics: particle morphology and size, sintered porosity, coating cross-section thickness.
- Failure analysis: fracture surface macro and micro morphology, corrosion products, crack path and origin, with stereo microscopy for low-magnification locating.