HOT
MMAS-18 · 2026-11-17 · +86 21 5748 2007
MMAS-18 Metallurgical Microscope (无限远)
Metallurgical Microscope · 无限远
- 物镜(明场)无限远平场消色差物镜PL 5X/0.12,工作距离:26.1mm
- 放大倍数50~600X
- 目镜筒倾斜30度,瞳距调节范围53-75mm
- 落射照明系统6V30W卤素灯,亮度可调
By submitting you agree to our privacy policy.
Overview
MMAS-18无限远正置透反射金相显微镜测量分析系统适用于对不透明物体或透明物体的显微观察。采用优良的无限远光学系统与模块化功能设计理念、可提供出色的光学性能与产品系统升级,实现透反射同步或者独立照明,偏光观察、暗场观察等功能,产品操作方便,造型美观,图像清晰,是生物学、金属学、矿物学、精密工程学、电子学等研究的理想仪器。MMAS-18系统配备了研润自主研发的MMAS测量分析系统以及MOS高端光学系统。
一、技术特点:
1、观察系统:铰链式观察镜筒,30度倾斜,单视度可调,可100%进行透光摄影。大视野平场广角目镜,视场范围直径22mm。配备无限远长距平场消色差物镜(无盖玻璃)。
2、机械载物台:双层机械式载物台,尺寸210*140mm;移动范围63*50mm。
3、落射照明系统:6V,30W卤素灯,亮度可调。不仅能对明视场观察,还能对偏光和暗视场观察法提供清晰的显微图像。内置视场光栏、孔径光栏能够有效调节视场衬度,且视场光阑中心可调。配置360度旋转的起偏器和检偏器,可实现偏光观察。转盘式滤色片组,带黄绿蓝三种滤色片和磨砂玻璃。翻盖式灯箱设计,方便更换灯泡。
4、选配的暗场观察系统:选配的明暗视场物镜与暗视场照明装置,消除了照明系统的有害光线。
5、透射照明系统:内置卤素灯照明装置,能提供清晰的显微图像,配置蓝滤色片与磨砂玻璃。阿贝聚光镜NA.1.25可上下升降;集光镜中内置视场光栏。
5、选配件:
5.1分化目镜:10X(直径22mm),格值0.1mm/格;
5.2明视场选配物镜:20、50、80、100(干式);
5.3明暗视场选配物镜:PLL5X/0.12(工作距离8.05)、PLL10X/0.25(工作距离7.86)、PLL20X/0.4(工作距离7.23)、PLL40X/0.6(工作距离3.0)、PLL50X/0.7(工作距离1.75)、PLL60X/0.7(工作距离1.65)、PLL80X/0.8(工作距离0.8)、PLL100X/0.85(工作距离0.4);
5.4适配镜:0.5X、1X、0.5带0.1mm/格分化尺;
5.5数码摄像机;
5.612V30W卤素灯;
5.7蓝、黄、绿滤色片;
5.812V50W卤素灯(用于暗场观察);
二、技术参数:
目镜
大视野 WF10X(Φ22mm)
物镜(明场)
无限远平场消色差物镜PL 5X/0.12,工作距离:26.1mm
无限远平场消色差物镜PL L10X/0.25,工作距离:20.2mm
无限远平场消色差物镜PL L40X/0.60,工作距离:3.98mm
无限远平场消色差物镜PL L60X/0.70,工作距离:2.08mm
放大倍数
50~600X
目镜筒
倾斜30度,瞳距调节范围53-75mm
落射照明系统
6V30W卤素灯,亮度可调
内置视场光栏、孔径光栏、黄绿蓝滤色片和磨砂玻璃转换装置,推拉式检偏器与起偏器
透射照明系统
6V30W卤素灯,亮度可调,
阿贝聚光镜NA1.25可上下升降,集光镜中内置视场光栏
调焦机构
粗微动同轴调焦, 微动格值:2μm,粗动松紧可调,带锁紧和限位装置
转换器
五孔(内向式滚珠内定位);
载物台
双层机械移动式(尺寸:210mmX140mm,移动范围:63mmX50mm)
外形尺寸
455*545*260
配备系统
主机+MMAS数据处理系统1套+MOS光学系统一套+电脑一套
MMAS-18 Metallurgical Microscope (无限远) supplied by CHWES. 10 key specifications available on request.
Specifications
| 物镜(明场) | 无限远平场消色差物镜PL 5X/0.12,工作距离:26.1mm |
|---|---|
| 放大倍数 | 50~600X |
| 目镜筒 | 倾斜30度,瞳距调节范围53-75mm |
| 落射照明系统 | 6V30W卤素灯,亮度可调 |
| 透射照明系统 | 6V30W卤素灯,亮度可调, |
| 调焦机构 | 粗微动同轴调焦, 微动格值:2μm,粗动松紧可调,带锁紧和限位装置 |
| 转换器 | 五孔(内向式滚珠内定位); |
| 载物台 | 双层机械移动式(尺寸:210mmX140mm,移动范围:63mmX50mm) |
| 外形尺寸 | 455*545*260 |
| 配备系统 | 主机+MMAS数据处理系统1套+MOS光学系统一套+电脑一套 |
* Generated by rule engine over the product database; for pre-selection only.
Working principle
The metallurgical microscope uses an infinity-corrected optical path with reflected Köhler illumination. Light passes the collector, field stop and aperture stop, is deflected by a semi-transparent mirror through the objective onto the specimen, and returns through the same objective to the eyepiece or camera.
- Bright field for routine microstructure, inclusions and decarburised layers.
- Dark field collects scattered light to reveal grain boundaries, cracks and non-metallic inclusions.
- Polarised light identifies anisotropic phases, spheroidised structures and coating stress.
- DIC converts tiny height differences into contrast, ideal for polished, unetched samples.
Objectives of 5× to 100× are combined with 10× eyepieces. Higher numerical aperture gives better resolution but shallower depth of field.
Process animation
- Sampling and preparation: sectioning, mounting, grinding, polishing, etching.
- Illumination and focus: select BF/DF/POL/DIC and focus.
- Image capture: trinocular port, 1× camera adapter, white balance.
- Scale calibration: calibrate µm per pixel with a stage micrometer.
- Measurement: grain size, case depth, coating thickness, inclusion rating.
Calculation & formulas
1. System magnification: M = objective × eyepiece × adapter, e.g. 40× / 10× / 1× = 400×.
2. Resolution: d = 0.61λ/NA (λ≈550 nm). A 40× objective with NA 0.65 resolves 0.52 µm; an NA 0.95 dry objective reaches 0.35 µm.
3. Depth of field scales with λ/NA² — higher NA, shallower depth; use low NA for fracture surfaces.
4. Grain size (GB/T 6394): at 100×, grains N per 645 mm² field follow N = 2G−1; counting 128 grains gives G = log2128 + 1 = 8. Intercept method: mean intercept L̄ = line length ÷ intercepts, G = −6.6437 lg L̄ (mm, 100×).
5. Effective case depth: distance to 550 HV1, fitted from a micro-hardness traverse and averaged over three positions.
Standards
| Standard | Title | Scope |
|---|---|---|
| GB/T 13298-2015 | Metallic materials — examination of microstructure | Microstructure rating |
| GB/T 6394-2017 | Determination of average grain size | Grain size |
| ASTM E3-11 | Guide for metallographic specimen preparation | Preparation |
| ASTM E112 | Determining average grain size | Grain size |
| ISO 643 | Steels — micrographic determination of grain size | Grain size |
Export projects often require dual GB and ASTM reports; the software ships both rating charts.
Selection guide
1. Surface or cross-section: stereo microscopes (HX-ZG7, XSZ) for fracture surfaces, solder joints and coatings; upright or inverted metallurgical microscopes (HX-4, HX-G series) for microstructure, case depth and inclusions.
2. Upright or inverted: upright for small specimens that are flipped often; inverted (HX-G3A/G4C/G5A) for large, heavy parts such as gears, shafts and tube sections that go straight onto the stage without re-mounting.
3. Optics set the ceiling: plan achromats cover routine rating; semi-apochromats or apochromats with a research stand (HX-G5A) are needed for 1000× precipitates and brightfield/darkfield/polarised switching.
4. Three levels of digitalisation: a 5 MP camera for images; camera plus analysis software (grain size, case depth, inclusions, porosity) for automatic rating and reports; motorised stage with scanning and stitching for unattended batches.
5. Do not forget accessories: polariser, darkfield, DIC, and a microhardness interface.
6. Room: an anti-vibration bench at 20±3 °C for research stands; keep preparation and microscopy rooms separate to avoid abrasive dust.
| Series | Type | Typical task | Recommended setup |
|---|---|---|---|
| HX-4A / HX-4B | Upright metallurgical | Routine structure, case depth | 5×/10×/40× + 5 MP camera |
| HX-G2A / G2B | Inverted | Batch samples, no re-mounting | Brightfield + simple polariser |
| HX-G3A | Trinocular inverted | Case depth, rating, reports | Camera + analysis software |
| HX-G4C / G5A | Research inverted | Darkfield/polarised/DIC | Semi-apochromat + motorised stage |
| HX-ZG7 / XSZ-146 | Stereo | Fracture, solder, low-mag locating | Zoom + ring light |
Common misconceptions: higher magnification is not better (numerical aperture limits resolution, 100× dry is the practical ceiling); ignoring stage travel so large samples do not fit; buying the stand without software and still rating by eye, which kills repeatability.
Test method
Preparation. Section perpendicular to the feature of interest. Keep hot-mounting below 150 °C for aluminium and quenched parts, or use cold mounting. Grind 320→600→800→1200, removing previous scratches at each step; polish with 3 µm then 1 µm diamond. Etchants: 4% nital for carbon steel (3–8 s), aqua regia or electrolytic for stainless, Keller for aluminium.
Examination. Locate a representative field at 5×/10×, then switch to higher power. Rate grain size to GB/T 6394 by comparison or intercept. Measure case depth at 500× with an ocular scale or calibrated software, averaging five readings.
Calibration. Verify µm/pixel daily with a stage micrometer, check against a certified specimen quarterly, record three fields per sample and archive images with scale bars.
Pitfalls. Over-etching widens boundaries and fakes decarburisation; residual scratches can be mistaken for cracks; rounded mounting edges inflate case depth. Keep an unetched specimen for coating and crack review.
Industry applications
- Steel and heat treatment: decarburised depth, carburised/nitrided case depth, grain size (GB/T 6394), non-metallic inclusions (GB/T 10561), banding and Widmanstätten rating.
- Non-ferrous metals: aluminium grain and recrystallisation, alpha/beta ratio in brass, twinning and corrosion morphology in magnesium.
- Welding and brazing: penetration, HAZ width, porosity and cracks, intermetallic thickness at dissimilar joints.
- Additive manufacturing: porosity, lack-of-fusion defects, melt-pool morphology in SLM parts, porosity repeatability within 0.2%.
- Bearings and gears: martensite rating, retained austenite, carbide network and banding, grinding burn and white layer.
- Electronics: IMC thickness, plating cross-sections, PCB micro-sections, gold wire ball bonds (stereo plus metallurgical).
- Powders and ceramics: particle morphology and size, sintered porosity, coating cross-section thickness.
- Failure analysis: fracture surface macro and micro morphology, corrosion products, crack path and origin, with stereo microscopy for low-magnification locating.