The contract limited straightness over 24 m to 0.01 mm; the old spirit-level method took two shifts with poor repeatability.
Solution: an HXJL300UH-0.1 with a 500 mm bridge, measured after two hours of thermal soak, evaluated by both end-point and minimum-zone methods, with an HXM2020 monitoring the cross direction.
Result: 8.2 µm minimum-zone (9.6 µm end-point) and 11 µm crosswise, all within tolerance; 65 minutes, repeatability ±0.4 µm.