BI-25 Biological Microscope (相衬、无限远)

Biological Microscope · 相衬、无限远

型番BI-25
  • 放大倍数40X~1000X
  • 目镜大视野WF10X(Φ22mm)
  • 无限远平场消色差物镜4X/0.10\工作距离21mm,10X/0.25\5mm,40X/0.65(弹簧)\0.66mm,100X/1.25(弹簧,油)\0.36mm
  • 目镜筒双目镜(倾斜30度)

By submitting you agree to our privacy policy.

01

製品概要

BI-25生物显微镜配备优良的无限远平场消色差物镜和大视野目镜,成像清晰,视野广阔。符合人机工程学的设计理念,采用低位调焦手轮,内向式物镜转换器与内置式提手设计,使操作更方便舒适,空间更广阔,仪器搬运更安全。产品可广泛应用于生物、医学、工业、农业等领域,是医疗、教学、科研等单位的理想仪器。
一、性能特点
1、配备优质的无限远光学系统,提供出色的光学性能;
2、高刚性主体,抗振性能高;
3、模块化设计思想,可以选配多种附件,用于相衬等装置;
4、超大机械式平台,适合快速检测;
5、大视野目镜,视场范围直径22mm;
二、技术参数:
放大倍数:40X~1000X;
目镜:大视野WF10X(Φ22mm);
无限远平场消色差物镜:4X/0.10\工作距离21mm,10X/0.25\5mm,40X/0.65(弹簧)\0.66mm,100X/1.25(弹簧,油)\0.36mm;
目镜筒:双目镜(倾斜30度);
调焦机构:粗微动同轴调焦, 粗动松紧可调,带锁紧和限位装置,微动格值:2μm;
转换器:四孔(内向式滚珠内定位);
载物台:双层机械移动式,尺寸210mmX140mm,移动范围:75mmX50mm;
阿贝聚光镜:N.A.1.25可上下升降;
滤色片:蓝滤色片、磨砂玻璃;
集光器:集光镜中内置视场光阑;
光源:6V/30W卤素灯,亮度可调;
三、选配配件:
1、分划:10X(Φ22mm、0.1mm/格);
2、物镜:无限远平场消色差物镜PL20X/0.4\工作距离8.8mm、60X/0.85\工作距离0.25mm;
3、相衬装置(目镜):对中望远镜;
4、相衬装置(无限远相衬平场消色差物镜):10X/0.25 PHP、20X/0.40 PHP、40X/0.65 PHP(弹簧)、100X/1.25 PHP(弹簧、油);
5、转盘式相衬聚光镜:PH-I;
6、转盘式相衬聚光镜:PH-II;
7、插板式相衬聚光镜;
8、拉板式相衬聚光镜;
9、滤色片:黄、绿滤色片;
10、转换器:五孔(内向式滚珠内定位);
11、摄影目镜:USB、VIDEO输出;

BI-25 Biological Microscope (相衬、无限远) supplied by CHWES. 11 key specifications available on request.

02

仕様

放大倍数40X~1000X
目镜大视野WF10X(Φ22mm)
无限远平场消色差物镜4X/0.10\工作距离21mm,10X/0.25\5mm,40X/0.65(弹簧)\0.66mm,100X/1.25(弹簧,油)\0.36mm
目镜筒双目镜(倾斜30度)
调焦机构粗微动同轴调焦, 粗动松紧可调,带锁紧和限位装置,微动格值:2μm
转换器四孔(内向式滚珠内定位)
载物台双层机械移动式,尺寸210mmX140mm,移动范围:75mmX50mm
阿贝聚光镜N.A.1.25可上下升降
滤色片蓝滤色片、磨砂玻璃
集光器集光镜中内置视场光阑
光源6V/30W卤素灯,亮度可调

* Generated by rule engine over the product database; for pre-selection only.

03

測定原理

The metallurgical microscope uses an infinity-corrected optical path with reflected Köhler illumination. Light passes the collector, field stop and aperture stop, is deflected by a semi-transparent mirror through the objective onto the specimen, and returns through the same objective to the eyepiece or camera.

  • Bright field for routine microstructure, inclusions and decarburised layers.
  • Dark field collects scattered light to reveal grain boundaries, cracks and non-metallic inclusions.
  • Polarised light identifies anisotropic phases, spheroidised structures and coating stress.
  • DIC converts tiny height differences into contrast, ideal for polished, unetched samples.

Objectives of 5× to 100× are combined with 10× eyepieces. Higher numerical aperture gives better resolution but shallower depth of field.

04

Process animation

  1. Sampling and preparation: sectioning, mounting, grinding, polishing, etching.
  2. Illumination and focus: select BF/DF/POL/DIC and focus.
  3. Image capture: trinocular port, 1× camera adapter, white balance.
  4. Scale calibration: calibrate µm per pixel with a stage micrometer.
  5. Measurement: grain size, case depth, coating thickness, inclusion rating.
0102030405
05

Calculation & formulas

1. System magnification: M = objective × eyepiece × adapter, e.g. 40× / 10× / 1× = 400×.

2. Resolution: d = 0.61λ/NA (λ≈550 nm). A 40× objective with NA 0.65 resolves 0.52 µm; an NA 0.95 dry objective reaches 0.35 µm.

3. Depth of field scales with λ/NA² — higher NA, shallower depth; use low NA for fracture surfaces.

4. Grain size (GB/T 6394): at 100×, grains N per 645 mm² field follow N = 2G−1; counting 128 grains gives G = log2128 + 1 = 8. Intercept method: mean intercept L̄ = line length ÷ intercepts, G = −6.6437 lg L̄ (mm, 100×).

5. Effective case depth: distance to 550 HV1, fitted from a micro-hardness traverse and averaged over three positions.

06

規格

StandardTitleScope
GB/T 13298-2015Metallic materials — examination of microstructureMicrostructure rating
GB/T 6394-2017Determination of average grain sizeGrain size
ASTM E3-11Guide for metallographic specimen preparationPreparation
ASTM E112Determining average grain sizeGrain size
ISO 643Steels — micrographic determination of grain sizeGrain size

Export projects often require dual GB and ASTM reports; the software ships both rating charts.

07

選定ガイド

1. Surface or cross-section: stereo microscopes (HX-ZG7, XSZ) for fracture surfaces, solder joints and coatings; upright or inverted metallurgical microscopes (HX-4, HX-G series) for microstructure, case depth and inclusions.

2. Upright or inverted: upright for small specimens that are flipped often; inverted (HX-G3A/G4C/G5A) for large, heavy parts such as gears, shafts and tube sections that go straight onto the stage without re-mounting.

3. Optics set the ceiling: plan achromats cover routine rating; semi-apochromats or apochromats with a research stand (HX-G5A) are needed for 1000× precipitates and brightfield/darkfield/polarised switching.

4. Three levels of digitalisation: a 5 MP camera for images; camera plus analysis software (grain size, case depth, inclusions, porosity) for automatic rating and reports; motorised stage with scanning and stitching for unattended batches.

5. Do not forget accessories: polariser, darkfield, DIC, and a microhardness interface.

6. Room: an anti-vibration bench at 20±3 °C for research stands; keep preparation and microscopy rooms separate to avoid abrasive dust.

SeriesTypeTypical taskRecommended setup
HX-4A / HX-4BUpright metallurgicalRoutine structure, case depth5×/10×/40× + 5 MP camera
HX-G2A / G2BInvertedBatch samples, no re-mountingBrightfield + simple polariser
HX-G3ATrinocular invertedCase depth, rating, reportsCamera + analysis software
HX-G4C / G5AResearch invertedDarkfield/polarised/DICSemi-apochromat + motorised stage
HX-ZG7 / XSZ-146StereoFracture, solder, low-mag locatingZoom + ring light

Common misconceptions: higher magnification is not better (numerical aperture limits resolution, 100× dry is the practical ceiling); ignoring stage travel so large samples do not fit; buying the stand without software and still rating by eye, which kills repeatability.

08

試験方法

Preparation. Section perpendicular to the feature of interest. Keep hot-mounting below 150 °C for aluminium and quenched parts, or use cold mounting. Grind 320→600→800→1200, removing previous scratches at each step; polish with 3 µm then 1 µm diamond. Etchants: 4% nital for carbon steel (3–8 s), aqua regia or electrolytic for stainless, Keller for aluminium.

Examination. Locate a representative field at 5×/10×, then switch to higher power. Rate grain size to GB/T 6394 by comparison or intercept. Measure case depth at 500× with an ocular scale or calibrated software, averaging five readings.

Calibration. Verify µm/pixel daily with a stage micrometer, check against a certified specimen quarterly, record three fields per sample and archive images with scale bars.

Pitfalls. Over-etching widens boundaries and fakes decarburisation; residual scratches can be mistaken for cracks; rounded mounting edges inflate case depth. Keep an unetched specimen for coating and crack review.

09

Industry applications

  • Steel and heat treatment: decarburised depth, carburised/nitrided case depth, grain size (GB/T 6394), non-metallic inclusions (GB/T 10561), banding and Widmanstätten rating.
  • Non-ferrous metals: aluminium grain and recrystallisation, alpha/beta ratio in brass, twinning and corrosion morphology in magnesium.
  • Welding and brazing: penetration, HAZ width, porosity and cracks, intermetallic thickness at dissimilar joints.
  • Additive manufacturing: porosity, lack-of-fusion defects, melt-pool morphology in SLM parts, porosity repeatability within 0.2%.
  • Bearings and gears: martensite rating, retained austenite, carbide network and banding, grinding burn and white layer.
  • Electronics: IMC thickness, plating cross-sections, PCB micro-sections, gold wire ball bonds (stereo plus metallurgical).
  • Powders and ceramics: particle morphology and size, sintered porosity, coating cross-section thickness.
  • Failure analysis: fracture surface macro and micro morphology, corrosion products, crack path and origin, with stereo microscopy for low-magnification locating.
10

Price and lead time for this model

By submitting you agree to our privacy policy.

⇄0比較仕様比較